Feasibility and clinical utility of handheld fundus cameras for retinal imaging.

Das Susmit, Kuht Helen J, De Silva Ian, Deol Sundeep S, Osman Lina, Burns Joyce, Sarvananthan Nagini, Sarodia Usman, Kapoor Bharat, Islam Tahir, Sampath Raghavan, Poyser Alicia, Konidaris Vasileios, Anzidei Rossella, Proudlock Frank A, Thomas Mervyn G

СтатьяПеревод в очереди

Аннотация

BACKGROUND/

OBJECTIVES

Handheld fundus cameras are portable and cheaper alternatives to table-top counterparts. To date there have been no studies comparing feasibility and clinical utility of handheld fundus cameras to table-top devices. We compare the feasibility and clinical utility of four handheld fundus cameras/retinal imaging devices (Remidio NMFOP, Volk Pictor Plus, Volk iNview, oDocs visoScope) to a table-top camera (Zeiss VisucamNM/FA).

SUBJECTS/

METHODS

Healthy participants (n = 10, mean age ± SD = 21.0 ± 0.9 years) underwent fundus photography with five devices to assess success/failure rates of image acquisition. Participants with optic disc abnormalities (n = 8, mean age ± SD = 26.8 ± 15.9) and macular abnormalities (n = 10, mean age ± SD = 71.6 ± 15.4) underwent imaging with the top three scoring fundus cameras. Images were randomised and subsequently validated by ophthalmologists masked to the diagnoses and devices used.

RESULTS

Image acquisition success rates (100%) were achieved in non-mydriatic and mydriatic settings for Zeiss, Remidio and Pictor, compared with lower success rates for iNview and oDocs. Image quality and gradeability were significantly higher for Zeiss, Remidio and Pictor (p < 0.0001) compared to iNview and oDocs. For cup:disc ratio estimates, similar levels of bias were seen for Zeiss (-0.09 ± SD:0.15), Remidio (-0.07 ± SD:0.14) and Pictor (-0.05 ± SD:0.16). Diagnostic sensitivities were highest for Zeiss (84.9%; 95% CI, 78.2-91.5%) followed by Pictor (78.1%; 95% CI, 66.6-89.5%) and Remidio (77.5%; 95% CI, 65.9-89.0%).

CONCLUSIONS

Remidio and Pictor achieve comparable results to the Zeiss table-top camera. Both devices achieved similar scores in feasibility, image quality, image gradeability and diagnostic sensitivity. This suggests that these devices potentially offer a more cost-effective alternative in certain clinical scenarios.

Для цитирования: Das Susmit, Kuht Helen J, De Silva Ian, Deol Sundeep S, Osman Lina, Burns Joyce, Sarvananthan Nagini, Sarodia Usman, Kapoor Bharat, Islam Tahir, Sampath Raghavan, Poyser Alicia, Konidaris Vasileios, Anzidei Rossella, Proudlock Frank A, Thomas Mervyn G. Feasibility and clinical utility of handheld fundus cameras for retinal imaging.. Eye (London, England). 2022. DOI: 10.1038/s41433-021-01926-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.