Pediatric Esophageal Button Battery Protocol Reduces Time From Presentation to Removal.

Goh Samantha, Siu Jennifer M, Philteos Justine, James Adrian L, Ostrow Olivia, McKinnon Nicole K, Everett Tobias, Levine Mark, Whyte Hilary, Lam Christopher Z, Propst Evan J, Wolter Nikolaus E

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Evaluate implementation of an institutional protocol to reduce the time to removal of esophageal button battery (BB) and increase use of mitigation strategies.

METHODS

We developed a protocol for esophageal BB management [Zakai's Protocol (ZP)]. All cases of esophageal BB impaction managed at a tertiary care center before and after implementation from 2011 to 2023 were reviewed. Time to BB removal, adherence to critical steps, and use of mitigation strategies (honey/sucralfate, acetic acid) were evaluated.

RESULTS

Fifty-one patients (38 pre-ZP, 13 post-ZP) were included. Median age was 2.3 years (IQR 1.3-3.4). After implementation, the time from arrival at the institution to arrival in the operating room (OR) reduced by 4.2 h [4.6 h (IQR 3.9-6.5) to 0.4 h (IQR 0.3-0.6), p < 0.001] and there was improvement in all management steps. The number of referrals direct to otolaryngology increased from 51% to 92%, arrival notification increased from 86% to 100%, avoidance of second x-ray increased from 63% to 100%, and direct transfer to OR increased from 92% to 100%. Adherence to mitigation strategies such as preoperative administration of honey or sucralfate increased from 0% to 38%, intraoperative use of acetic acid from 3% to 77%, and nasogastric tube insertion from 53% to 92%.

CONCLUSION

Implementation of ZP substantially reduced the time to BB removal and the use of mitigation strategies in our tertiary care institution. Additional strategies focused on prevention of BB ingestion, and shortening the transfer time to the tertiary care hospital are required to prevent erosive complications.

LEVEL OF EVIDENCE: 3, Case-series Laryngoscope, 134:5170-5177, 2024.

Для цитирования: Goh Samantha, Siu Jennifer M, Philteos Justine, James Adrian L, Ostrow Olivia, McKinnon Nicole K, Everett Tobias, Levine Mark, Whyte Hilary, Lam Christopher Z, Propst Evan J, Wolter Nikolaus E. Pediatric Esophageal Button Battery Protocol Reduces Time From Presentation to Removal.. The Laryngoscope. 2024. DOI: 10.1002/lary.31607.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.