Feasibility, safety and effectiveness of mapping system assisted conduction system pacing: a single-center prospective study.

Wang Liang, Yang Suxia, Tang Baopeng, Wang Feifei, Sang Wanyue, Han Yafan, Wang Lu, Zhou Xianhui, Zhang Jianghua, Xing Qiang, Tuerhong Zukela, Xiaokereti Jiasuoer, Guo Yankai, Li Yaodong

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

To assess pacing and electrophysiological parameters, as well as mid-term outcomes, among patients undergoing His bundle pacing (HBP) guided by KODEX-EPD (a novel mapping system). Consecutive patients undergoing conduction system pacing (CSP) for bradycardia indications were evaluated. Procedural and fluoroscopic times and pacing characteristics were compared between conventional fluoroscopy (the standard group, N = 20 cases) and KODEX-EPD mapping system guided group (the KODEX group, N = 20cases) at CSP implantation and all patients were followed at 6-month. HBP was achieved in all patients (the standard group 20/20 and the KODEX group 20/20). There was no difference in the mean procedure time between the two groups (63.7 ± 9.3 vs. 78.2 ± 25.1 min, p = 0.33). Compared with the standard group, the KODEX group significantly reduced the intraoperative X-ray exposure time (3.8 ± 0.5 vs. 19.3 ± 5.1 min, p < 0.05) and X-ray dose (23.6 ± 5.4 vs. 120.2 ± 38.3 mGy, p < 0.05). There were no significant differences in atrial impedance (643.0 ± 98.8 vs. 591.5 ± 92.1 Ω, p = 0.09), atrial sensing (2.9 ± 0.8 vs. 2.5 ± 0.8 mV, p = 0.08), ventricular sensing (12.8 ± 2.4 vs. 13.3 ± 3.3 mV, p = 0.63),atrial pacing threshold (1.0 ± 0.2 vs. 1.0 ± 0.1 V/0.4 ms, p = 0.81) and ventricular pacing threshold (1.0 ± 0.2 vs. 0.9 ± 0.1 V/0.4 ms, p = 0.63) between two groups, There were statistical differences in ventricular impedance (640.0 ± 80.3 vs. 702.0 ± 86.1 Ω, p < 0.05). There was no statistical significance in pacing parameters between the two groups at 6 months after procedure (p > 0.05). During the 6-months follow-up period, no adverse events occurred in the two groups. It can be concluded that KODEX-EPD can safely guide His bundle branch pacing lead implantation with reduced fluoroscopic time and dose without lengthening the procedure time.

Для цитирования: Wang Liang, Yang Suxia, Tang Baopeng, Wang Feifei, Sang Wanyue, Han Yafan, Wang Lu, Zhou Xianhui, Zhang Jianghua, Xing Qiang, Tuerhong Zukela, Xiaokereti Jiasuoer, Guo Yankai, Li Yaodong. Feasibility, safety and effectiveness of mapping system assisted conduction system pacing: a single-center prospective study.. Scientific reports. 2023. DOI: 10.1038/s41598-023-36546-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.