MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1442-2042.2008.02181.x

Медицинская библиотека · International journal of urology : official journal of the Japanese Urological Association · 2008

Photoselective vaporization of the prostate using high power (80 W) KTP laser: one year follow up of the first 101 patients in Japan.

Hori Yasuhide, Kuromatsu Isao, Sugimura Yoshiki

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

We present one year observations on Photoselective Vaporization of the Prostate (PVP) of 101 men with benign prostatic hyperplasia (BPH) to investigate its safety and efficacy.

METHODS

101 patients underwent Photoselective Vaporization of the Prostate (PVP) using 80 W Potassium-titanyl-phosphate (KTP) laser 17 patients were being treated with oral anticoagulant therapy, and anticoagulants were stopped before operation. Baseline characteristics, perioperative data, adverse events and postoperative outcome were evaluated immediate postoperatively, and at 2 weeks and 1, 3, 6 and 12 months postoperatively were recorded.

RESULTS

With all 101 patients KTP laser vaporization was performed successfully. There was minimal blood loss and none of patients need blood transfusion. No major complication occurred intraoperatively or postoperatively. At 1, 3, 6, and 12 months mean International Prostate Symptom Score index (IPSS) decreased from 20.3 preoperatively to 8.9, 6.9, 6.2 and 7.2. Mean QQL score decreased from 5.1 to 2.3, 1.7, 1.5 and 1.6. Mean urinary peak flow increased from 7.5 ml per second to 15.6, 16.7 16.7 and 16.7 respectively. Complication was mild, included transient dysuria (8.9%).

CONCLUSIONS

Photoselective vaporization of the prostate (PVP) using 80W Potassium-titanyl-phosphate (KTP) laser for benign prostatic hyperplasia (BPH) proved to be an effective and safe procedure for our patients including those treated with oral anticoagulants.

Для цитирования: Hori Yasuhide, Kuromatsu Isao, Sugimura Yoshiki. Photoselective vaporization of the prostate using high power (80 W) KTP laser: one year follow up of the first 101 patients in Japan.. International journal of urology : official journal of the Japanese Urological Association. 2008. DOI: 10.1111/j.1442-2042.2008.02181.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.