MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The Journal of urology · 1995

Variability of pressure-flow analysis parameters in repeated cystometry in patients with benign prostatic hyperplasia.

Rosier P F, de la Rosette J J, Koldewijn E L, Debruyne F M, Wijkstra H

СтатьяПеревод в очереди

Аннотация

Urodynamic investigation becomes increasingly important in the diagnosis of bladder outflow obstruction in patients with benign prostatic hyperplasia. To date, different methods for evaluation of the pressure-flow relationship and quantification of the grade of obstruction are available. Models for pressure-flow analysis are briefly explained. The variability of the parameters is investigated by evaluation of 75 patients in whom 2 sequential voidings during urodynamic investigation were analyzed. The results showed that in 87% of these patients individual maximum flow differences of first and second voidings were less than 2 ml. per second. Individual detrusor pressure at maximum flow differences were less than 15 cm. water in 80% of these patients, while in 80% the intra-individual variation of the pressure-flow results was less than 15 cm. water for the minimal voiding pressure parameters (minimal urethral opening detrusor pressure and urethral resistance factor). For the pressure-flow parameter that defines the theoretical urethral lumen during voiding, the variation was less than 1.5 mm.2 in 84% of the patients. Patients with larger intra-individual differences are discussed. We concluded that the observed, aforementioned differences can be regarded as an indication of normal intra-individual variability of voiding during urodynamic investigation. This intra-individual variability, however, seldom leads to a change in the clinical grade of bladder outflow obstruction. We conclude that investigators involved in therapeutic trials of benign prostatic hyperplasia must be aware of this intra-individual variability of micturition, since this variability is greater than the refined scale of the pressure-flow analysis models.

Для цитирования: Rosier P F, de la Rosette J J, Koldewijn E L, Debruyne F M, Wijkstra H. Variability of pressure-flow analysis parameters in repeated cystometry in patients with benign prostatic hyperplasia.. The Journal of urology. 1995.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.