MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0377-1237(05)80112-1

Медицинская библиотека · Medical journal, Armed Forces India · 2011

Local Anaesthesia for Fiberoptic Intubation : A Comparison of Three Techniques.

Sethi N, Tarneja V K, Madhusudanan T P, Shouche S

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The successful conduct of fiberoptic aided intubation is dependent upon effective local anaesthesia. The aim of the study was to compare three different methods of anaesthetizing the airway.

METHODS

60 adult patients (American Society of Anaesthesiologists status I-III and Mallampati class III & IV), scheduled for elective surgery, received sedation followed by spraying of the nares and posterior pharyngeal wall with 4% lignocaine. Thereafter the patients received 4 ml of 4% lignocaine either by transtracheal injection (n=20, group A), via intubating fiberscope (Pentax F1-10P2) using 'spray as you go' technique (n=20, group B) or by nebulizer (Devilbiss 5610W) 20 min before intubation, (n=20, group C). Patients were asked to score the procedure using visual analog scale (VAS) and severity scores. Episodes of coughing, choking, stridor, extra / total local anaesthetic used and intubation times were recorded. Patients were monitored continuously for vital parameters.

RESULTS

Group B patients showed better VAS scores with shorter intubation times and had a lower incidence of coughing and choking. The endoscopists' VAS scores also showed a preference for group B.

CONCLUSION

In conclusion the 'spray as you go' technique was safe, provided effective local anaesthesia and was preferred by both patients and endoscopists.

Для цитирования: Sethi N, Tarneja V K, Madhusudanan T P, Shouche S. Local Anaesthesia for Fiberoptic Intubation : A Comparison of Three Techniques.. Medical journal, Armed Forces India. 2011. DOI: 10.1016/s0377-1237(05)80112-1.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.