MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/lary.28419

Медицинская библиотека · The Laryngoscope · 2019

Self-reported mini olfactory questionnaire (Self-MOQ): A simple and useful measurement for the screening of olfactory dysfunction.

Zou Lai-Quan, Linden Lena, Cuevas Mandy, Metasch Marie-Luise, Welge-Lüssen Antje, Hähner Antje, Hummel Thomas

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

Olfactory dysfunction is a common problem. However, too little attention has been paid to questionnaires used to evaluate quantitative olfactory dysfunction. Therefore, the current study aimed to develop a simple self-reported Mini Olfactory Questionnaire (Self-MOQ) for the screening of quantitative olfactory dysfunction in clinical practice.

METHODS

Two hundred and eighty-five patients who had subjective complaints of olfactory disorder participated. The Sniffin' Sticks test score was used to define functional anosmia, hyposmia, or normosmia. We assessed the factor structure as well as internal consistency, convergent validity, and discrimination performance.

RESULTS

The results showed that the final version of the Self-MOQ included only one factor with five items. The Self-MOQ has a good internal reliability (Cronbach's α = 0.84) and validity (r = -0.60, P < 0.001). The receiver operating characteristic analyses indicated that the Self-MOQ as compared to a visual analogue scale (VAS) is an effective measure for discriminating normosmic from hyposmic/anosmic patients, anosmic patients, and hyposmic patients.

CONCLUSION

The Self-MOQ is a simple, reliable and valid questionnaire to screen olfactory dysfunction in clinical practice that appears to be superior to the use of VASs but does not replace olfactory testing.

LEVEL OF EVIDENCE: 4 Laryngoscope, 2019.

Для цитирования: Zou Lai-Quan, Linden Lena, Cuevas Mandy, Metasch Marie-Luise, Welge-Lüssen Antje, Hähner Antje, Hummel Thomas. Self-reported mini olfactory questionnaire (Self-MOQ): A simple and useful measurement for the screening of olfactory dysfunction.. The Laryngoscope. 2019. DOI: 10.1002/lary.28419.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.