MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijpharm.2014.09.053

Медицинская библиотека · International journal of pharmaceutics · 2014

Prolonged local retention of subcutaneously injected polymers monitored by noninvasive SPECT imaging.

Kojima Chie, Niki Yuichiro, Ogawa Mikako, Magata Yasuhiro

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Polymers are widely applied to drug delivery systems because polymers are generally excreted from the body more slowly than small molecules. Subcutaneous injection is one plausible means of administration. In this study, the in vivo behaviors of subcutaneously injected polymers, linear poly(glutamic acid) (Poly-Glu), acetylated dendrimer (Ac-den) and collagen peptide-conjugated dendrimer (CP-den), were investigated. Single photon emission computed tomography (SPECT) imaging was used to noninvasively monitor the in vivo behaviors. Diethylenetriaminepentaacetic acid (DTPA) was conjugated to these polymers, which were labeled with radioactive (111)In. These (111)In-DTPA-bearing polymers (Poly-Glu-DTPA, Ac-den-DTPA and CP-den-DTPA) and unconjugated DTPA were subcutaneously injected into tumor-bearing mice, which were subjected to SPECT imaging. These (111)In-DTPA-bearing polymers were largely retained at the injection site for at least 1 day, whereas the unconjugated DTPA was rapidly cleared from the whole body through excretion. Poly-Glu-DTPA and Ac-den-DTPA were partly accumulated in the kidney (and the liver), but the CP-den-DTPA was not. However, these (111)In-DTPA-bearing polymers were accumulated in the liver and the kidney following intravenous administration. These results indicate that the subcutaneously injected polymers did not largely gain substantial access to the systemic circulation, which is useful for a depot of drug around the injection site.

Для цитирования: Kojima Chie, Niki Yuichiro, Ogawa Mikako, Magata Yasuhiro. Prolonged local retention of subcutaneously injected polymers monitored by noninvasive SPECT imaging.. International journal of pharmaceutics. 2014. DOI: 10.1016/j.ijpharm.2014.09.053.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.