MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10792-021-02196-z

Медицинская библиотека · International ophthalmology · 2022

Longitudinal evaluation of retinal thickness and OCTA parameters before and following silicone oil removal in eyes with macula-on and macula-off retinal detachments.

Bayraktar Zerrin, Pehlivanoglu Seren, Hagverdiyeva Samira, Albayrak Sinan, Karakaya Muharrem, Bayraktar Şükrü

СтатьяПеревод в очереди

Аннотация

BACKGROUND

To investigate the longitudinal retinal vascular and structural alterations by using OCTA following successful repair of retinal detachment (RD) by using silicone oil (SO) endotamponade.

METHODS

A prospective cohort study was performed on 24 eyes of 24 subjects; 17 of them with macula-off and seven with macula-on RD. At least four OCTA scans were generated for each study eye; two before and two after SO removal (SOR). At each session, retinal thickness (RT), vascular density (VD) in the superficial (SCP) and deep capillary plexuses (DCP) and foveal avascular zone(FAZ) size were measured within the fovea, parafovea and whole macular image. The changes in repeated measures of the same parameters especially before and after SOR were performed and compared within macula-on and macula-off groups and between fellow eyes.

RESULTS

"In the macula-off eyes, RT measurements within the whole macula, fovea and parafovea reduced as compared with their fellow eyes(p < 0.0001, p = 0.001 and p < 0.0001, respectively) and did not improve after SOR. Additionally, all of the whole macular, foveal, and parafoveal VD measurements at SCP and foveal VD at DCP were less than their fellow eyes after SOR (p = 0.026, p = 0.023 p = 0.026, and p = 0.002, respectively). In macula-on eyes, RT measurements decreased within the parafovea and whole macular area before SOR (p = 0.018 and p = 0.011, respectively) but improved after SOR. Also, VD measurements did not change during follow-up and were not statistically different than their fellow eyes (p > 0.05). FAZ enlargement was found in eyes with macular-off RD after SOR, whereas it was not observed with macular-on RD (p = 0.038and p = 0.237, respectively).

CONCLUSIONS

Treatment of macula-off RD with SO tamponade has been associated with vascular retinal abnormalities which did not improve following SOR. On the contrary, successful treatment of RD with SO tamponade in macula-on eyes VD measurements of SCP and DCP were not statistically different than their fellow eyes.

Для цитирования: Bayraktar Zerrin, Pehlivanoglu Seren, Hagverdiyeva Samira, Albayrak Sinan, Karakaya Muharrem, Bayraktar Şükrü. Longitudinal evaluation of retinal thickness and OCTA parameters before and following silicone oil removal in eyes with macula-on and macula-off retinal detachments.. International ophthalmology. 2022. DOI: 10.1007/s10792-021-02196-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.