The effects of sufentanil or morphine added to hyperbaric bupivacaine in spinal anaesthesia for caesarean section.
Аннотация
BACKGROUND AND
OBJECTIVE
The quality of spinal anaesthesia, often used for Caesarean section, can be improved by adding an opioid to the local anaesthetic. This study compared the quality of anaesthesia, postoperative analgesia, and adverse effects on mother and neonate when either sufentanil 5 microg or morphine 0.2 mg was added to intrathecal hyperbaric bupivacaine for Caesarean section.
METHODS
This prospective, randomized and double-blind study encompassed 54 females undergoing Caesarean section. Spinal anaesthesia was obtained with 2 mL of 0.5% bupivacaine supplemented with either 0.2 mg morphine or 5 microg sufentanil. Characteristics of spinal block, intraoperative analgesia, maternal and neonatal side-effects and the time to first request for analgesics were assessed.
RESULTS
There were no differences in the onset time of sensory block, time to sensory block to T10, time to highest sensory block, highest sensory block level, time to regression of sensory block to T10 level and time to resolution of motor blockade. Perioperative haemodynamic parameters, neonatal Apgar scores, neurological and adaptive capacity scores, umbilical blood gas values, sedation scores, nausea-vomiting and pruritus incidences were similar in both groups. The time to the first request for an analgesic was significantly longer (19.5 +/- 4.7 h vs. 6.3 +/- 5.2 h) in patients given morphine (P < 0.05).
CONCLUSIONS
The addition of 5 microg sufentanil or 0.2 mg morphine to hyperbaric bupivacaine for Caesarean section both provided safe and effective anaesthesia. Morphine increased the duration of postoperative analgesia compared with sufentanil without increasing maternal or neonatal side-effects.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.