MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1515/jpm-2020-0203

Медицинская библиотека · Journal of perinatal medicine · 2020

Predictive values of clinical parameters and biophysical and biochemical markers in the first trimester for the detection of small-for-gestational age fetuses.

Antunes Irene Reali, Lobo Guilherme Antonio Rago, Araujo Júnior Edward, Pares David Baptista da Silva

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

To evaluate the predictive values of maternal characteristics, biophysical parameters (mean arterial pressure [MAP] and Doppler uterine artery measurements), and biochemical parameters (pregnancy-associated plasma protein A [PAPP-A] and placental growth factor [PlGF]) alone and in association for small-for-gestational age (SGA) fetuses.

METHODS

We performed a retrospective analysis of a prospective observational study that evaluated 615 pregnant women in the first trimester using ultrasonography. For all the women, information regarding clinical and obstetric histories, MAP, and uterine artery mean pulsatility index (UtA-PI), and blood samples for analysis of biochemical markers (PAPP-A and PlGF) were obtained. The patients were grouped according to birth weight as follows: group I (n=571), >10th percentile (control); group II (n=44), <10th percentile; and group III (n=34), <5th percentile. The predictive values of the variables for the detection of SGA fetuses were calculated using a logistic regression model and an analysis of the area under the receiver-operating characteristic curve (AUC).

RESULTS

The sensitivity rates of the maternal characteristics, biophysical markers (MAP and UtA-PI), biochemical markers (PAPP-A and PlGF), and the association between them were: 23.3, 32.5, 25, and 30% respectively, at a false-positive (FP) rate of 10%, in group II and 26.5, 26.5, 23.5, and 23.5%, respectively, at a FP rate of 10% in group III.

CONCLUSIONS

The predictive performances of the combination of maternal characteristics and biophysical and biochemical parameters were unsatisfactory, with a slight improvement in the predictive capacity for SGA fetuses <10th percentile.

Для цитирования: Antunes Irene Reali, Lobo Guilherme Antonio Rago, Araujo Júnior Edward, Pares David Baptista da Silva. Predictive values of clinical parameters and biophysical and biochemical markers in the first trimester for the detection of small-for-gestational age fetuses.. Journal of perinatal medicine. 2020. DOI: 10.1515/jpm-2020-0203.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.