MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00134-008-1046-3

Медицинская библиотека · Intensive care medicine · 2008

Influence of insertion site on central venous catheter colonization and bloodstream infection rates.

Gowardman John R, Robertson Iain K, Parkes Scott, Rickard Claire M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To compare colonization and catheter-related bloodstream infection (CR-BSI) rates among three insertion sites (subclavian, internal jugular, femoral) used for central venous catheter (CVC) placement.

DESIGN

Twenty-four-month prospective study, with relative effects analyzed by Cox proportional hazards regression.

SETTING

Eight-bed intensive care unit.

PATIENTS: Four hundred and ten critically ill patients requiring CVC placement.

MEASUREMENTS AND

RESULTS

All short-term multi-lumen CVCs, including antimicrobial-coated devices, were studied with management standardized. Six hundred and five CVCs (4,040 catheter days) were analyzed. Colonization and CR-BSI incidence were, respectively, 15.1 (95% CI 13.5-21.0) and 1.8 (95% CI 1.2-4.2) per 1,000 catheter-days. Colonization was higher at the internal jugular (HR 3.64; 95% CI 1.32-10.00; p=0.01) and femoral (HR 5.15; 95% CI 1.82-14.51; p=0.004) sites than at the subclavian site. The femoral site carried a greater risk of being colonized by non-S. epidermidis species than the subclavian and internal jugular sites combined (HR 4.15; 95% CI 1.79-9.61; p=0.001). CVCs inserted in the Department of Emergency Medicine were more colonized than those inserted in the ICU or operating room (HR 2.66; 95% CI 1.27-5.56; p=0.01), and CVCs were less colonized in females than in males (HR 0.49; 95% CI 0.26-0.89; p=0.02). No difference in CR-BSI rates was noted between the three sites.

CONCLUSIONS

Colonization was lowest at the subclavian site. Regional differences exist with respect to type of pathogen isolated. Colonization was influenced by insertion location and gender. The incidence of CR-BSI was not different.

Для цитирования: Gowardman John R, Robertson Iain K, Parkes Scott, Rickard Claire M. Influence of insertion site on central venous catheter colonization and bloodstream infection rates.. Intensive care medicine. 2008. DOI: 10.1007/s00134-008-1046-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.