MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-018-5867-3

Медицинская библиотека · European radiology · 2018

Evaluation of pain reduction and height restoration post vertebral augmentation using a polyether ether ketone (PEEK) polymer implant for the treatment of split (Magerl A2) vertebral fractures: a prospective, long-term, non-randomized study.

Velonakis Georgios, Filippiadis Dimitrios, Spiliopoulos Stavros, Brountzos Elias, Kelekis Nikolaos, Kelekis Alexis

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

The purposes of the study were to evaluate the safety and long-term efficacy of augmented vertebroplasty using a polyether ether ketone (PEEK) implant, for the treatment of lumbar or thoracic vertebral fractures (A2 according to the Magerl's AO classification) and to analyze pain reduction, height restoration, and complications during a 2-year follow-up period.

METHODS

Prospective non-randomized evaluation was performed for 21 painful split vertebral fractures (20 patients, 14 females, 6 males; mean age 72.80 ± 10.991) treated with percutaneous vertebral augmentation using a PEEK device, under fluoroscopic guidance. Pain before the procedure and after 6, 12, and 24 months was evaluated using a numeric visual scale (NVS) questionnaire. Imaging was performed by CT and X-rays. The minimum craniocaudal diameter at the level of the fracture and the maximum craniocaudal diameter at the middle of the fractured vertebra were measured. Statistical analysis was performed to evaluate pain decrease and height restoration.

RESULTS

Successful implant positioning was achieved in all cases. No major clinical complications were observed. Comparing the mean pain scores at baseline (8.69 ± 1.138) and the first day after the treatment (1.19 ± 1.424), there was a decrease of 7.50 NVS units (p < 0.001). Minimum and maximum vertebral body heights were increased after the procedure 56.58% and 13.7% respectively (p < 0.001). Both pain relief and height restoration remained statistically significant (p < 0.001) during the follow-up period.

CONCLUSION

A2 Magerl thoracic or lumbar fractures could be successfully treated with PEEK implant-assisted vertebral augmentation. Randomized studies with larger sample sizes should be done to confirm the effectiveness of the technique.

KEY POINTS: • Vertebral augmentation using a PEEK implant for the treatment of A2 Magerl lumbar or thoracic vertebral fractures seems to be effective both in terms of pain reduction and height restoration. • Effects on pain reduction and height restoration have a long-term duration. • The technique seems to be safe for the treatment of A2 Magerl fractures, without major complications in our study group.

Для цитирования: Velonakis Georgios, Filippiadis Dimitrios, Spiliopoulos Stavros, Brountzos Elias, Kelekis Nikolaos, Kelekis Alexis. Evaluation of pain reduction and height restoration post vertebral augmentation using a polyether ether ketone (PEEK) polymer implant for the treatment of split (Magerl A2) vertebral fractures: a prospective, long-term, non-randomized study.. European radiology. 2018. DOI: 10.1007/s00330-018-5867-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.