MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/1471-2466-9-51

Медицинская библиотека · BMC pulmonary medicine · 2009

Effects of acute hypoventilation and hyperventilation on exhaled carbon monoxide measurement in healthy volunteers.

Cavaliere Franco, Volpe Carmen, Gargaruti Riccardo, Poscia Andrea, Di Donato Michele, Grieco Giovanni, Moscato Umberto

СтатьяПеревод в очереди

Аннотация

BACKGROUND

High levels of exhaled carbon monoxide (eCO) are a marker of airway or lung inflammation. We investigated whether hypo- or hyperventilation can affect measured values.

METHODS

Ten healthy volunteers were trained to achieve sustained end-tidal CO2 (etCO(2)) concentrations of 30 (hyperventilation), 40 (normoventilation), and 50 mmHg (hypoventilation). As soon as target etCO(2) values were achieved for 120 sec, exhaled breath was analyzed for eCO with a photoacoustic spectrometer. At etCO(2) values of 30 and 40 mmHg exhaled breath was sampled both after a deep inspiration and after a normal one. All measurements were performed in two different environmental conditions: A) ambient CO concentration = 0.8 ppm and B) ambient CO concentration = 1.7 ppm.

RESULTS

During normoventilation, eCO mean (standard deviation) was 11.5 (0.8) ppm; it decreased to 10.3 (0.8) ppm during hyperventilation (p < 0.01) and increased to 11.9 (0.8) ppm during hypoventilation (p < 0.01). eCO changes were less pronounced than the correspondent etCO(2) changes (hyperventilation: 10% Vs 25% decrease; hypoventilation 3% Vs 25% increase). Taking a deep inspiration before breath sampling was associated with lower eCO values (p < 0.01), while environmental CO levels did not affect eCO measurement.

CONCLUSIONS

eCO measurements should not be performed during marked acute hyperventilation, like that induced in this study, but the influence of less pronounced hyperventilation or of hypoventilation is probably negligible in clinical practice.

Для цитирования: Cavaliere Franco, Volpe Carmen, Gargaruti Riccardo, Poscia Andrea, Di Donato Michele, Grieco Giovanni, Moscato Umberto. Effects of acute hypoventilation and hyperventilation on exhaled carbon monoxide measurement in healthy volunteers.. BMC pulmonary medicine. 2009. DOI: 10.1186/1471-2466-9-51.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.