MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pan.13218

Медицинская библиотека · Paediatric anaesthesia · 2017

Different predictivity of fluid responsiveness by pulse pressure variation in children after surgical repair of ventricular septal defect or tetralogy of Fallot.

Han Ding, Pan Shoudong, Wang Xiaonan, Jia Qingyan, Luo Yi, Li Jia, Ou-Yang Chuan

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Pulse pressure variation derived from the varied pulse contour method is based on heart-lung interaction during mechanical ventilation. It has been shown that pulse pressure variation is predictive of fluid responsiveness in children undergoing surgical repair of ventricular septal defect. Right ventricle compliance and pulmonary vascular capacitance in children with tetralogy of Fallot are underdeveloped as compared to those in ventricular septal defect. We hypothesized that the difference in the right ventricle-pulmonary circulation in the two groups of children would affect the heart-lung interaction and therefore pulse pressure variation predictivity of fluid responsiveness following cardiac surgery.

METHODS

Infants undergoing complete repair of ventricular septal defect (n=38, 1.05±0.75 years) and tetralogy of Fallot (n=36, 1.15±0.68 years) clinically presenting with low cardiac output were enrolled. Fluid infusion with 5% albumin or fresh frozen plasma was administered. Pulse pressure variation was recorded using pressure recording analytical method along with cardiac index before and after fluid infusion. Patients were considered as responders to fluid loading when cardiac index increased ≥15%. Receiver operating characteristic curves analysis was used to assess the accuracy and cutoffs of pulse pressure variation to predict fluid responsiveness.

RESULTS

The pulse pressure variation values before and after fluid infusion were lower in tetralogy of Fallot children than those in ventricular septal defect children (15.2±4.4% vs 19.3±4.4%, P<.001; 11.6±3.8 vs 15.4±4.3%, P<.001, respectively). In ventricular septal defect children, 27 were responders and 11 nonresponders. Receiver operating characteristic curve area was 0.89 (95% confidence interval, 0.77-1.01) and cutoff value 17.4% with a sensitivity of 0.89 and a specificity of 0.91. In tetralogy of Fallot children, 26 were responders and 10 were nonresponders. Receiver operating characteristic curve area was 0.79 (95% CI, 0.64-0.94) and cutoff value 13.4% with a sensitivity of 0.81 and a specificity of 0.80.

CONCLUSION

Pulse pressure variation is predictive of fluid responsiveness in ventricular septal defect and tetralogy of Fallot patients following cardiac surgery.

Для цитирования: Han Ding, Pan Shoudong, Wang Xiaonan, Jia Qingyan, Luo Yi, Li Jia, Ou-Yang Chuan. Different predictivity of fluid responsiveness by pulse pressure variation in children after surgical repair of ventricular septal defect or tetralogy of Fallot.. Paediatric anaesthesia. 2017. DOI: 10.1111/pan.13218.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.