MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/medicina61091566

Медицинская библиотека · Medicina (Kaunas, Lithuania) · 2025

Comparative Diagnostic and Prognostic Performance of SWI and T2-Weighted MRI in Cerebral Microbleed Detection Following Acute Ischemic Stroke: A Meta-Analysis and SPOT-CMB Study.

Tan Rachel, Spring Kevin J, Killingsworth Murray, Bhaskar Sonu

СтатьяМетаанализСистематический обзорПеревод в очереди

Аннотация

Background and

Objectives

Cerebral microbleeds (CMBs) are increasingly being considered as potential biomarkers of small vessel disease and cerebral vulnerability, particularly in patients with acute ischemic stroke (AIS). Accurate detection is crucial for prognosis and therapeutic decision-making, yet the relative utility of susceptibility-weighted imaging (SWI) versus T2*-weighted imaging (T2*) remains uncertain. Materials and

Methods

We conducted a systematic review and meta-analysis (SPOT-CMB, Susceptibility-weighted imaging and Prognostic Outcomes in Acute Stroke-Cerebral Microbleeds study) of 80 studies involving 28,383 AIS patients. Pooled prevalence of CMBs was estimated across imaging modalities (SWI, T2*, and both), and stratified analyses examined variation by demographic, clinical, and imaging parameters. Meta-analytic odds ratios assessed associations between CMB presence and key outcomes: symptomatic intracerebral hemorrhage (sICH), hemorrhagic transformation (HT), and poor functional outcome (modified Rankin Scale score 3-6) at 90 days. Diagnostic performance was assessed using summary receiver operating characteristic curves.

Results

Pooled CMB prevalence was higher with SWI (36%; 95% CI 31-41) than T2* (25%; 95% CI 22-28). CMB presence was associated with increased odds of sICH (OR 2.22; 95% CI 1.56-3.16), HT (OR 1.33; 95% CI 1.01-1.75), and poor 90-day outcome (OR 1.61; 95% CI 1.39-1.86). However, prognostic performance was modest, with low sensitivity (e.g., AUC for sICH: 0.29) and low diagnostic odds ratios. SWI outperformed T2* in detection but offered limited prognostic gain. Access to SWI remains limited in many settings, posing challenges for global implementation.

Conclusions

SWI detects CMBs more frequently than T2* in AIS patients and shows stronger associations with adverse outcomes, supporting its value for risk stratification. However, prognostic accuracy remains limited, and our GRADE appraisal indicated only moderate certainty for functional outcomes, with lower certainty for diagnostic accuracy due to heterogeneity and imprecision. These findings highlight the clinical utility of SWI but underscore the need for standardized imaging protocols and high-quality prospective studies.

Для цитирования: Tan Rachel, Spring Kevin J, Killingsworth Murray, Bhaskar Sonu. Comparative Diagnostic and Prognostic Performance of SWI and T2-Weighted MRI in Cerebral Microbleed Detection Following Acute Ischemic Stroke: A Meta-Analysis and SPOT-CMB Study.. Medicina (Kaunas, Lithuania). 2025. DOI: 10.3390/medicina61091566.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.