Use of near-infrared spectroscopy as a physiologic monitor for intra-abdominal hypertension.

Widder Sandy, Ranson Michael K, Zygun David, Knox Linda, Laupland Kevin B, Laird Philip, Ball Chad G, Kirkpatrick Andrew W

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Intra-abdominal hypertension (IAH) is increasingly recognized as an important parameter in critically ill (ICU) patients. IAH affects perfusion to all abdominal components including the abdominal wall (AW). Near infrared spectroscopy (NIRS) measures changes in three chromophores including oxygenated hemoglobin (HbO2), deoxygenated hemoglobin (Hb), and cytochrome aa3 (Cyt), providing information concerning dysoxia. We sought to examine whether NIRS measurement of the AW was safe, and correlated with intra-abdominal pressure (IAP) in ICU patients.

METHODS

A NIU-Pro001 system recorded NIRS data over 24 hours from the AW of 9 ICU patients at risk for IAH. IAP was recorded from the bladder. Changes in chromophore values are interpolated from best-fit polynomial curves.

RESULTS

Sixty-six paired IAP and NIRS readings were taken from 9 ICU (4-12 observations/patient) patients. No measurement related adverse reactions occurred. The mean (range) first values measured in these patients were; IAP 17.2 mm Hg (9-31); HbO2 0.41 micromol/L (-8.4 to 7.6); Hb 2.6 micromol/L (-3.1 to 12.2); and Cyt 0.65 micromol/L (-3.4 to 4.8). A significant, inverse (or negative) association was found between DeltaNIRS HbO2 level and DeltaIAP (coefficient, -0.1588; p = 0.008). No association was found between DeltaNIRS Hb or DeltaCyt and DeltaIAP.

CONCLUSION

NIRS of the AW appears safe. NIRS measurement of changes in HbO2 appears to be associated with DeltaIAP, and warrant further study in greater numbers of ICU patients with more frequent IAP readings, over longer periods of critical illness.

Для цитирования: Widder Sandy, Ranson Michael K, Zygun David, Knox Linda, Laupland Kevin B, Laird Philip, Ball Chad G, Kirkpatrick Andrew W. Use of near-infrared spectroscopy as a physiologic monitor for intra-abdominal hypertension.. The Journal of trauma. 2008. DOI: 10.1097/ta.0b013e31814695dd.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.