MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.27489

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2018

Bilateral branch pulmonary artery valve implantation in repaired tetralogy of fallot.

Bansal Neha, Kobayashi Daisuke, Forbes Thomas J, Du Wei, Zerin Jeffrey M, Joshi Aparna, Turner Daniel R

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Transcatheter, bilateral branch pulmonary artery (PA) valve implantation is a novel treatment for patients with severe pulmonary insufficiency and oversized right ventricle (RV) outflow tract. There is scarce data on efficacy and safety of this approach.

METHODS

This was a retrospective study of 8 patients with repaired tetralogy of fallot (TOF) who underwent bilateral branch PA valve implantation. Demographics, echocardiography, cardiac catheterization, and axial imaging data were reviewed. Variables were compared by a paired sample t-test.

RESULTS

All patients were adult sized (weight 43-99 kg) with oversized RV outflow tract not suitable for conventional transcatheter pulmonary valve implantation. Staged bare metal PA stenting followed by valve implantation (interval 3-5 months) was technically successful in 7 patients with one stent embolization. In another patient, proximal stent migration prevented placement of bilateral pulmonary valve stents. There were a total of 14 valved branch PA stents placed (Melody valve n = 9, Sapien XT n = 2, Sapien 3 n = 3). In the 7 patients undergoing successful branch pulmonary valve placement, at median follow up of 10 months (range 3 months to 6 years), 13 (93%) valves had none/trivial insufficiency on echocardiography. Prevalve and postvalve implantation cardiac magnetic resonance imaging in five patients showed significant reduction of indexed RV end-diastolic volume (152 ± 27 to 105 ± 15 mL/m2 , P < .001).

CONCLUSIONS

Transcatheter, bilateral branch PA valve implantation was technically feasible with satisfactory efficacy and safety in patients with repaired TOF, severe pulmonary insufficiency, and oversized RV outflow tracts. Elimination of pulmonary insufficiency with this method resulted in reduced RV end-diastolic volume. This approach can be offered as an alternative to surgery, particularly in patients considered high risk for standard surgical placement and who are not candidates for the newer self-expanding valve prosthesis for placement in RV outflow tracts larger than 30 mm diameter.

Для цитирования: Bansal Neha, Kobayashi Daisuke, Forbes Thomas J, Du Wei, Zerin Jeffrey M, Joshi Aparna, Turner Daniel R. Bilateral branch pulmonary artery valve implantation in repaired tetralogy of fallot.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2018. DOI: 10.1002/ccd.27489.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.