MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mlr.0b013e3181f380e0

Медицинская библиотека · Medical care · 2011

Accuracy of diagnostic mammography at facilities serving vulnerable women.

Goldman L Elizabeth, Walker Rod, Miglioretti Diana L, Smith-Bindman Rebecca, Kerlikowske Karla, National Cancer Institute Breast Cancer Surveillance Consortium

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

BACKGROUND

Breast cancer missed on diagnostic mammography may contribute to delayed diagnoses, whereas false-positive results may lead to unnecessary invasive procedures. Whether accuracy of diagnostic mammography at facilities serving vulnerable women differs from other facilities is unknown.

OBJECTIVE

To compare the interpretive performance of diagnostic mammography at facilities serving vulnerable women to those serving nonvulnerable women.

DESIGN

We examined 168,251 diagnostic mammograms performed at Breast Cancer Surveillance Consortium facilities from 1999 to 2005. We used hierarchical logistic regression to compare sensitivity, false positive rates, and cancer detection rates.

SUBJECTS: Women aged between 40 and 80 years underwent diagnostic mammography to evaluate an abnormal screening mammogram or breast problem.

MEASURES: Facilities were assigned vulnerability indices according to the populations served based on the proportion of mammograms performed on women with lower educational attainment, racial/ethnic minority status, limited household income, or rural residences.

RESULTS

Sensitivity of diagnostic mammography did not vary significantly across vulnerability indices adjusted for patient-level characteristics, but false-positive rates for diagnostic mammography examinations to evaluate a breast problem were higher at facilities serving vulnerable women defined as those with lower educational attainment (odds ratio [OR], 1.39; 95% confidence interval [CI]: 1.08, 1.79); racial/ethnic minorities (OR, 1.32; 95% CI: 0.98, 1.76); limited income (OR, 1.34; 95% CI: 1.08, 1.66); and rural residence (OR, 1.55; 95% CI: 1.27, 1.88).

CONCLUSIONS

Diagnostic mammography to evaluate a breast problem at facilities serving vulnerable women had higher false positive rates than at facilities serving nonvulnerable women. This may reflect concerns that vulnerable populations may be less likely to follow-up after abnormal diagnostic mammography or concerns that such populations have higher cancer prevalence.

Для цитирования: Goldman L Elizabeth, Walker Rod, Miglioretti Diana L, Smith-Bindman Rebecca, Kerlikowske Karla, National Cancer Institute Breast Cancer Surveillance Consortium. Accuracy of diagnostic mammography at facilities serving vulnerable women.. Medical care. 2011. DOI: 10.1097/mlr.0b013e3181f380e0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.