OBJECTIVE

To study the method for synthesis of 2-hydroxyl-5- butyramidobenzoic acid and test its effect on acetic acid-induced colitis in rats.

METHODS

2-hydroxyl-5-butyramidobenzoic acid was synthesized from 5-aminosalicylic acid and butyric acid by amidation, esterification and hydrolization. The effect of 2-hydroxyl-5-butyramidobenzoic acid on acetic acid enema-induced colitis in rats was investigated.

RESULTS

The structure of 2-hydroxyl-5-butyramidobenzoic acid was identified by IR and 1H-NMR. After treatment with acetic acid, the colon mucosal damage index (CMDI), fecal occult blood (OB) test, and activity of myelperoxidase (MPO) increased significantly in the rats as compared to the control levels. 2-hydroxyl-5- butyramidobenzoic acid obviously reduced the CMDI and OB, and reduced the level of MPO in the rats with colitis.

CONCLUSION

The synthesis of 2-hydroxyl-5-butyramidobenzoic acid requires only mild conditions with simple procedures, and the synthesized 2-hydroxyl-5-butyramidobenzoic acid shows obvious therapeutic effects on mucosal damage of in rats with acetic acid-induced colitis.

Для цитирования: Shi Rui-cai, Xing Jian-feng, Liu Zhao-guo, Yuan Zhi-zhao, Zhang San-qi, Bian Xiao-li, Zeng Ai-guo. [Synthesis of 2-hydroxyl-5-butyramidobenzoic acid and its effect on acetic acid-induced colitis in rats].. Nan fang yi ke da xue xue bao = Journal of Southern Medical University. 2009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.