Doppler ultrasound to assess the pharmacodynamic effects of splanchnic vasoactive compounds.
Аннотация
AIMS: In search of noninvasive biomarkers to assess the pharmacodynamic effects of portal pressure-lowering drugs, the reproducibility of flow measurements in the superior mesenteric artery was evaluated using Doppler ultrasound.
METHODS
A reproducibility study was conducted in 15 healthy male volunteers (18-50 y). Eight ultrasound measurements were performed for each subject: 2 observers each conducted 2 measurements during 2 separate visits. The following flow parameters were captured: peak systolic velocity (PSV), end diastolic velocity (EDV), pulsatility index (PI), volume flow (VF) and vessel diameter. Reproducibility was assessed by the intraclass correlation coefficient.
RESULTS
Results are presented as intraclass correlation coefficient [95% confidence interval]. The flow parameters PSV, EDV, PI and VF correlated excellently within observer during visit 1 (0.888 [0.748-0.953], 0.910 [0.793-0.962], 0.844 [0.656-0.933] and 0.916 [0.857-0.951], respectively) and visit 2 (0.925 [0.829-0.968], 0.942 [0.863-0.976], 0.883 [0.719-0.954] and 0.915 [0.855-0.951], respectively). Measurements conducted during 2 separate visits by 1 observer correlated well to excellently for PSV, EDV, PI and VF (0.756 [0.552-0.875], 0.836 [0.694-0.916], 0.807 [0.631-0.904] and 0.839 [0.783-0.882], respectively). Measurements conducted by 2 distinct observers correlated well to excellently for PSV, EDV and VF during visit 1 (0.813 [0.584-0.922], 0.884 [0.597-0.945] and 0.786 [0.575-0.899], respectively) and visit 2 (0.779 [0.498-0.912], 0.861 [0.672-0.945], 0.810 [0.553-0.926], respectively). Vessel diameter measurements were poorly reproducible.
CONCLUSION
Doppler ultrasound is a reproducible method for flow measurements in the superior mesenteric artery in a standardized group of healthy volunteers. Therefore, it is a promising technique to assess pharmacodynamic effects of splanchnic vasoactive compounds in early clinical drug development.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.