BACKGROUND

Combining bilateral pulmonary artery banding with arterial duct stenting, the hybrid approach achieves stage 1 palliation for hypoplastic left heart syndrome with different flow characteristics than those after the surgical Norwood procedures. Accordingly, we used computational modeling to assess some of these differences, including influence on systemic and cerebral oxygen deliveries.

METHODS AND

RESULTS

A 3-dimensional computational model of hybrid palliation was developed by the finite volume method, along with models of the Norwood operation with a modified Blalock-Tausig or right ventricle-to-pulmonary artery shunt. Hybrid circulation was modeled with a 7-mm ductal stent and bilateral pulmonary artery banding to a 2-mm diameter. A 3.5-mm conduit was used in the Blalock-Tausig shunt model, whereas a 5-mm conduit was used in the right ventricle-to-pulmonary artery shunt model. Coupled to all the models was an identical hydraulic network that described the entire circulatory system based on pre-stage 2 hemodynamics. This clinically validated multiscale approach predicts flow dynamics, as well as global cardiac output, mixed venous oxygen saturation, and systemic and cerebral oxygen delivery. Compared with either of the Norwood models, the hybrid palliation had higher pulmonary-to-systemic flow ratio and lower cardiac output. Total systemic oxygen delivery was markedly reduced in the hybrid palliation (Blalock-Tausig shunt 591, right ventricle-to-pulmonary artery shunt 640, and hybrid 475 mL · min(-1) · m(-2)). Cerebral oxygen delivery was similarly lower in the hybrid palliation.

CONCLUSIONS

These computational results suggest that the hybrid approach may provide inferior systemic and cerebral oxygen deliveries compared with either of the 2 surgical Norwood procedures before stage 2 palliation.

Для цитирования: Hsia Tain-Yen, Cosentino Daria, Corsini Chiara, Pennati Giancarlo, Dubini Gabriele, Migliavacca Francesco, Modeling of Congenital Hearts Alliance (MOCHA) Investigators. Use of mathematical modeling to compare and predict hemodynamic effects between hybrid and surgical Norwood palliations for hypoplastic left heart syndrome.. Circulation. 2011. DOI: 10.1161/circulationaha.110.010769.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.