MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/10641960802069848

Медицинская библиотека · Clinical and experimental hypertension (New York, N.Y. : 1993) · 2008

Determinants of self-measured pulse rate profile in medicated hypertensives: the Jichi Morning Surge-1 (JMS-1) study.

Kabutoya Tomoyuki, Ishikawa Joji, Hoshide Satoshi, Eguchi Kazuo, Shibasaki Seiichi, Matsui Yoshio, Ishikawa Shizukiyo, Pickering Thomas G, Shimada Kazuyuki, Kario Kazuomi, JMS-1 Study Group

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Recently, it was reported that high pulse rate (PR), which was measured using by self-measured blood pressure (BP) monitoring at home, was associated with cardiovascular risk. However, the predictor of high PR at home in treated hypertensives is unknown. In this study, we studied the predictor of high PR and evaluated pulse rate variability (PRV).

METHODS

In the JMS-1 study, 611 hypertensive outpatients were recruited. Self-measured BP monitoring was conducted consecutively twice in the morning and evening for three days. PR analysis was conducted using the average of these two measurements for three days (six readings in total). We defined home PR as the mean of these six readings. Home PRV was defined as the standard deviation of these six readings.

RESULTS

Multivariate linear regression analysis demonstrated that current smoking (beta = 0.12, p = 0.002), diabetes (beta = 0.16, p < 0.001), lack of angiotensin-converting enzyme (ACE) inhibitor use (beta = 0.10, p = 0.008), decreased brain-type natriuretic peptide (BNP; beta = 0.17, p < 0.001), and elevated home diastolic blood pressure (beta = 0.14, p = 0.009) were determinants of high PR. Determinants of decreased home PRV were female gender (beta = 0.10, p < 0.03) and increased hemoglobin A1c (HbA1c; beta = 0.15, p < 0.001). When we divided the patients into four groups according to home PR and its variability, hypertensives whose home PR was high and variability was low were found to have high HbA1c (ANOVA, p > 0.05).

CONCLUSIONS

Smoking habit, diabetes, lack of ACE inhibitor use, and low BNP value were determinants of home PR, and female gender and higher HbA1c were significantly associated with its low variability. Home PR and its variability may be useful for detecting high-risk hypertensive patients, particularly with autonomic neuropathy.

Для цитирования: Kabutoya Tomoyuki, Ishikawa Joji, Hoshide Satoshi, Eguchi Kazuo, Shibasaki Seiichi, Matsui Yoshio, Ishikawa Shizukiyo, Pickering Thomas G, Shimada Kazuyuki, Kario Kazuomi, JMS-1 Study Group. Determinants of self-measured pulse rate profile in medicated hypertensives: the Jichi Morning Surge-1 (JMS-1) study.. Clinical and experimental hypertension (New York, N.Y. : 1993). 2008. DOI: 10.1080/10641960802069848.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.