MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/carj/4316574

Медицинская библиотека · Canadian respiratory journal · 2025

Plasma β-Endorphin and Neuropeptide Y as Candidate Biomarkers for Predicting Obstructive Sleep Apnea Syndrome: A Preliminary Study.

Li Meng-Lin, Yang Yi, Huang Qian-Yun, Liu Jian-Yong

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Background and

Objective

Given the involvement of neuropeptides in the pathophysiology of obstructive sleep apnea syndrome (OSAS), this study investigated the associations between plasma levels of β-endorphin (β-EP) and neuropeptide Y (NPY) and OSAS severity and evaluated their potential as predictive biomarkers.

Methods

A total of 48 snoring patients undergoing polysomnography (PSG) were categorized into non-OSAS, mild, moderate, and severe OSAS groups (n = 12 per group) based on the apnea-hypopnea index (AHI). Plasma levels of β-EP and NPY were measured using ELISA. Statistical analyses included one-way ANOVA, Spearman's correlation, and receiver operating characteristic (ROC) curve analysis to assess predictive performance.

Results

Plasma β-EP levels exhibited significant elevation in moderate (p=0.003) and severe OSAS groups (p=0.032) compared to the non-OSAS group. Notably, NPY levels demonstrated marked differences across all OSAS severity groups (p < 0.01), with significantly higher concentrations observed in mild, moderate, and severe OSAS patients versus non-OSAS controls (p < 0.01). A progressive increase in NPY levels was observed with advancing OSAS severity, accompanied by statistically significant intergroup differences (p < 0.01). Correlation analyses revealed strong positive associations between NPY levels and both BMI (p < 0.0001) and AHI (p < 0.0001). In contrast, β-EP correlated positively with AHI (p < 0.0001) but not with BMI (p=0.0931). ROC curve analysis identified β-EP (cutoff: 9.405 ng/L) as a moderate predictor of OSAS (AUC = 0.7986, p < 0.01; sensitivity: 72.22%, specificity: 83.33%). Strikingly, NPY (cutoff: 19.29 ng/L) exhibited perfect discriminative capacity (AUC = 1, p < 0.0001; sensitivity: 97.22%, specificity: 100%).

Conclusions

Plasma β-EP and NPY levels are associated with OSAS severity and may serve as potential biomarkers. However, further validation in larger cohorts is needed to confirm their clinical utility.

Для цитирования: Li Meng-Lin, Yang Yi, Huang Qian-Yun, Liu Jian-Yong. Plasma β-Endorphin and Neuropeptide Y as Candidate Biomarkers for Predicting Obstructive Sleep Apnea Syndrome: A Preliminary Study.. Canadian respiratory journal. 2025. DOI: 10.1155/carj/4316574.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.