DOI 10.1016/j.jcjo.2024.05.011
Relation between change of effective lens position and toric IOL rotation after toric IOL implantation.
Аннотация
OBJECTIVE
To evaluate the relationship between change of effective lens position (ELP) and toric intraocular lens (IOL) rotation in patients with increasing postoperative refractive astigmatism after successful toric IOL implantation.
METHODS
The subjects include 61 people (61 eyes) with increasing residual astigmatism >0.5 D 3 months after successful toric IOL implantation. Clinical measurements included preoperative, 1-week, and 1-, 2-, and 3-month postoperative visual acuity; refraction; keratometer; anterior and posterior corneal astigmatism; ELP by Scheimpflug camera imaging; and IOL axis by slit-lamp biomicroscopic photograph with pupil dilation.
RESULTS
Residual astigmatism in postoperative month 3 (0.81 ± 0.50 D) is higher than that at postoperative week 1 (0.41 ± 0.38 D; p < 0.05). ELP decreased by 264.44 ± 163.25 μm, and the IOL rotated by 2.91 ± 1.44 degrees from week 1 to month 3 (p < 0.05). The ELP change had a positive correlation with IOL rotation (R2 = 0.383; p = 0.006), and the postoperative refractive astigmatic change had a positive correlation with ELP change (R2 = 0.272; p = 0.027) and IOL rotation (R2 = 0.272; p = 0.0001) from week 1 to month 3.
CONCLUSION
ELP change can influence toric IOL rotation and increase residual astigmatism after toric IOL implantation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.