Combined Use of MITRACLIP and Ventricular ASSIST Devices in Cardiogenic Shock: MITRA-ASSIST Registry.

Rivero-Santana Borja, Jurado-Roman Alfonso, Pascual Isaac, Li Chi Hion, Jimenez Pilar, Estevez-Loureiro Rodrigo, Cepas-Guillén Pedro, Benito-González Tomás, Serrador Ana, De La Torre-Hernandez Jose Maria, Avanzas Pablo, Fernandez-Peregrina Estefania, Nombela Luis, Caneiro-Queija Berenice, Freixas Xavier, Fernandez-Vazquez Felipe, Amat-Santos Ignacio, Lee Dae-Hyun, Leon Victor, Arzamendi Dabit, Moreno Raul, Galeote Guillermo

СтатьяПеревод в очереди

Аннотация

Background

Patients with cardiogenic shock (CS) and mitral regurgitation (MI) have a prohibitive risk that contraindicates surgical treatment. Although the feasibility of transcatheter edge-to-edge therapy (TEER) has been demonstrated in this setting, the benefit of the combined use of TEER with mechanical circulatory support devices (MCS) has not been studied. The aim of this study was to evaluate the clinical outcomes of TEER in patients with MCS.

Methods

The MITRA-ASSIST study is a retrospective multicentre Spanish registry that included patients with MR and CS who underwent TEER in combination with MCS. The primary endpoint was death from any cause at 12 months. The secondary endpoint was a composite of death from any cause or hospitalisation for heart failure at 12 months.

Results

A total of twenty-four patients in nine high-volume Spanish centres (66.2 (51-82) years, 70.8% female, EuroSCORE II 20.4 ± 17.8) were included. Acute ST-elevation myocardial infarction was the main CS aetiology (56%), and the most implanted MCS was the intra-aortic balloon pump (82.6%), followed by ECMO (8.7%), IMPELLACP® (4.3%), or a combination of both (4.3%). Procedural success was 95.8%, with 87.5% in-hospital survival. At 12-month follow-up, 25.0% of patients died, and 33.3% had a composite event of death from any cause or hospitalisation for heart failure.

Conclusions

TEER in patients with concomitant CS and MR who require MCS appears to be a promising therapeutic alternative with a high device procedural success rate and acceptable mortality and heart failure readmission rates at follow-up.

Для цитирования: Rivero-Santana Borja, Jurado-Roman Alfonso, Pascual Isaac, Li Chi Hion, Jimenez Pilar, Estevez-Loureiro Rodrigo, Cepas-Guillén Pedro, Benito-González Tomás, Serrador Ana, De La Torre-Hernandez Jose Maria, Avanzas Pablo, Fernandez-Peregrina Estefania, Nombela Luis, Caneiro-Queija Berenice, Freixas Xavier, Fernandez-Vazquez Felipe, Amat-Santos Ignacio, Lee Dae-Hyun, Leon Victor, Arzamendi Dabit, Moreno Raul, Galeote Guillermo. Combined Use of MITRACLIP and Ventricular ASSIST Devices in Cardiogenic Shock: MITRA-ASSIST Registry.. Journal of clinical medicine. 2024. DOI: 10.3390/jcm13154408.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.