MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0041-1740236

Медицинская библиотека · Methods of information in medicine · 2021

Measurement Performance of Activity Measurements with Newer Generation of Apple Watch in Wheelchair Users with Spinal Cord Injury.

Benning Nils-Hendrik, Knaup Petra, Rupp Rüdiger

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The level of physical activity (PA) of people with spinal cord injury (SCI) has an impact on long-term complications. Currently, PA is mostly assessed by interviews. Wearable activity trackers are promising tools to objectively measure PA under everyday conditions. The only off-the-shelf, wearable activity tracker with specific measures for wheelchair users is the Apple Watch.

OBJECTIVES

This study analyzes the measurement performance of Apple Watch Series 4 for wheelchair users and compares it with an earlier generation of the device.

METHODS

Fifteen participants with subacute SCI during their first in-patient phase followed a test course using their wheelchair. The number of wheelchair pushes was counted manually by visual inspection and with the Apple Watch. Difference between the Apple Watch and the rater was analyzed with mean absolute percent error (MAPE) and a Bland-Altman plot. To compare the measurement error of Series 4 and an older generation of the device a t-test was calculated using data for Series 1 from a former study.

RESULTS

The average of differences was 12.33 pushes (n = 15), whereas participants pushed the wheelchair 138.4 times on average (range 86-271 pushes). The range of difference and the Bland-Altman plot indicate an overestimation by Apple Watch. MAPE is 9.20% and the t-test, testing for an effect of Series 4 on the percentage of error compared with Series 1, was significant with p < 0.05.

CONCLUSION

Series 4 shows a significant improvement in measurement performance compared with Series 1. Series 4 can be considered as a promising data source to capture the number of wheelchair pushes on even grounds. Future research should analyze the long-term measurement performance during everyday conditions of Series 4.

Для цитирования: Benning Nils-Hendrik, Knaup Petra, Rupp Rüdiger. Measurement Performance of Activity Measurements with Newer Generation of Apple Watch in Wheelchair Users with Spinal Cord Injury.. Methods of information in medicine. 2021. DOI: 10.1055/s-0041-1740236.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.