MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2460/ajvr.23.07.0166

Медицинская библиотека · American journal of veterinary research · 2023

The dilutional volume of morphine and xylazine administered via caudal epidural catheter affects cranial spread of analgesia in healthy standing horses.

Floriano Dario, Gorenberg Emma, Watkins Amanda, Hopster Klaus

Randomized Controlled Trial, VeterinaryСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To test the influence of increasing injectate volumes on the regional effects of xylazine and morphine epidural analgesia, with the hypothesis that increasing volume produces more cranial spread of analgesia as determined by thermal threshold (TT) testing.

ANIMALS: 6 university-owned research/teaching horses (2 mares, 4 geldings) deemed healthy on physical examination and basic lameness evaluation, aged 6-19 years and weighing 420-560 kg, were used in this prospective, randomized, blinded, cross-over experimental study.

METHODS

After routine placement of a caudal epidural catheter, all animals were subsequently instrumented with a TT testing system at the withers (Location A), the cranial (Location B), and caudal (Location C) abdominal area, over the tuber coxae (Location D), and the hind limb dorsal pasterns (Location E). All horses underwent five testing cycles with 0.2 mg/kg morphine and 0.2 mg/kg xylazine diluted to 20, 35, 50, 75, and 100 mL. TT testing was performed at 2, 4, 6, 8, and 10 hours by blinded investigators.

RESULTS

With increased epidural volume, significantly greater cranial spread of analgesic effect was noted. All epidural volumes caused significant changes in TT testing at location E but only the largest volume resulted in a significant TT testing change at location A.

CLINICAL RELEVANCE: Volume influences the regional effects of caudal epidural analgesia in horses but might affect analgesic reliability.

Для цитирования: Floriano Dario, Gorenberg Emma, Watkins Amanda, Hopster Klaus. The dilutional volume of morphine and xylazine administered via caudal epidural catheter affects cranial spread of analgesia in healthy standing horses.. American journal of veterinary research. 2023. DOI: 10.2460/ajvr.23.07.0166.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.