MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/crj.13174

Медицинская библиотека · The clinical respiratory journal · 2020

Comparison of 3-months treatment adherence and estimating residual apnea hypopnea index between home versus in-laboratory auto-titrating positive airway pressure titration.

Aydin Guclu Ozge, Ursavas Ahmet, Kasapoglu Fikret, Ocakoglu Gokhan, Karadag Mehmet

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

PURPOSE: We aimed to assess the accuracy of home titration in estimating apnea hypopnea index (AHI) and optimal pressure values and to compare improvements in subjective daytime sleepiness, sleep quality and quality of life, along with 3-months treatment adherence of patients that received at-home versus in-laboratory auto-titrating positive airway pressure (APAP) titration.

MATERIALS AND

METHODS

In patients with a diagnosis of obstructive sleep apnea syndrome (OSAS), a study arm of laboratory attended APAP titration was compared with a study arm of home titration using an APAP device for three days. Subjective questionnaires were evaluated before and after 3 months of treatment.

RESULTS

Fifty-three patients with newly diagnosed OSAS were enrolled. There was a significant positive correlation between PSG AHI and APAP AHI (rs  = 0.43, P = 0.003) and the fixed pressure for the APAP arm was positively correlated with the APAP PSG arm of the study (rs  = 0.71, P < 0.001). When the Bland-Altman graphs were compared, it was seen that the measurements obtained by the APAP AHI method were 0.3 units higher than the PSG AHI measurements, and that the mean of the measurement differences between the two methods was not different than 0 (P [H0 : Mean = 0] = 0.551). After 3 months of treatment, average nightly use was slightly higher in the APAP arm (P = 0.387).

CONCLUSIONS

The results indicate that both titration methods were not clinically inferior in terms of a fixed optimal pressure, residual events, 3-months treatment adherence and change in subjective sleepiness, sleep quality and quality of life after treatment.

Для цитирования: Aydin Guclu Ozge, Ursavas Ahmet, Kasapoglu Fikret, Ocakoglu Gokhan, Karadag Mehmet. Comparison of 3-months treatment adherence and estimating residual apnea hypopnea index between home versus in-laboratory auto-titrating positive airway pressure titration.. The clinical respiratory journal. 2020. DOI: 10.1111/crj.13174.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.