Detection of Malpositioned VP Shunt Catheter by Radionuclide CSF Cisternography.

Jo Nahyun, Edhayan Gautam, Owji Shahin, Villanueva-Meyer Javier, Bhargava Peeyush

Клинический случайСтатьяПеревод в очереди

Аннотация

A 37-year-old man presented with a 2-week history of abdominal pain, headaches, nausea, vomiting, and leukocytosis. Medical history includes congenital hydrocephalus, with a ventriculoperitoneal shunt placed several years ago. Radionuclide cerebrospinal fluid cisternography shows curvilinear activity in the abdomen, in the pattern of small and large bowel loops, suggesting that the tip of the catheter is inside a small bowel loop. No activity is seen in the intraperitoneal compartment. CT of the abdomen and pelvis followed by laparoscopic surgery confirmed the findings.

Для цитирования: Jo Nahyun, Edhayan Gautam, Owji Shahin, Villanueva-Meyer Javier, Bhargava Peeyush. Detection of Malpositioned VP Shunt Catheter by Radionuclide CSF Cisternography.. Clinical nuclear medicine. 2023. DOI: 10.1097/rlu.0000000000004525.