MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/01.cir.66.3.649

Медицинская библиотека · Circulation · 1982

Serial thallium-201 myocardial imaging after dipyridamole infusion: diagnostic utility in detecting coronary stenoses and relationship to regional wall motion.

Leppo J, Boucher C A, Okada R D, Newell J B, Strauss H W, Pohost G M

СтатьяПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

After a 4-minute i.v. dipyridamole infusion, 0.14 mg/kg/min, serial thallium-201 scans were obtained in 60 patients undergoing cardiac catheterization. Forty patients had significant (greater than or equal to 50% stenosis) coronary artery disease (CAD), and 20 patients had normal coronary arteries or trivial lesions. The images were graded qualitatively for thallium activity by three observers. Sensitivity was 93% (37 of 40) and specificity was 80% (16 of 20). The sensitivity and specificity of the thallium-201 study were not affected by the extent of CAD, the presence of Q waves, or propranolol therapy. Twenty-seven of 37 patients who had initial defects (73%) had complete thallium redistribution of one or more defects. Patient-by-patient analysis using a regression model of all patients showed that the fate of a segmental thallium defect predicted abnormal wall motion by angiography better than ECG Q waves. The presence of propranolol therapy or collaterals did not significantly affect the thallium redistribution results. We conclude that qualitative interpretation by multiple observers of thallium images after dipyridamole infusion is a highly sensitive and specific test for CAD. After dipyridamole, as with exercise stress, the extent of thallium redistribution is related to the degree of myocardial wall motion abnormality.

Для цитирования: Leppo J, Boucher C A, Okada R D, Newell J B, Strauss H W, Pohost G M. Serial thallium-201 myocardial imaging after dipyridamole infusion: diagnostic utility in detecting coronary stenoses and relationship to regional wall motion.. Circulation. 1982. DOI: 10.1161/01.cir.66.3.649.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.