MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1211/jpp/61.04.0008

Медицинская библиотека · The Journal of pharmacy and pharmacology · 2009

Discrepancies between predicted and observed rates of intravenous gentamicin delivery for neonates.

Sherwin Catherine M T, McCaffrey Frances, Broadbent Roland S, Reith David M, Medlicott Natalie J

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

This study aimed to investigate intravenous infusions as used in the neonatal intensive care setting, to determine the effect of gentamicin dose (mg), gentamicin concentrations (mg/ml), flow rate (ml/h) and flush volume (ml) upon the length of infusion time.

METHODS

Intravenous infusions were set up to simulate administration of gentamicin to neonates. Dextrose (10%, w/v) was administered as the primary intravenous fluid at 3.8 or 18.7 ml/h. Gentamicin doses (0.5 mg/0.2 ml, 2 mg/0.2 ml, 2.5 mg/1.0 ml, or 10 mg/1.0 ml) were delivered into the intravenous line at a T-connection using a Graseby pump over 35 min. This was followed by a saline flush of 1 or 2 ml over a further 35 min. At the end of each experiment a 2 ml 0.9% saline bolus was given. Analysis of gentamicin collected at 5-min intervals was by an HPLC method.

KEY FINDINGS: The experiment demonstrated that under the infusion conditions neonates weighing 2.5 kg would receive only 80% of the drug at 60 min, increasing to 90-95% by 75 min. In extremely low birth weight neonates (0.5 kg), even lower percentage of gentamicin recovery occurred. At 60 min only 60% of the intended gentamicin dose had been delivered and this increased to only 70% by 75 min.

CONCLUSIONS

The delivery of gentamicin administered by intravenous infusion is substantially extended in extremely low birth weight neonates. This appeared to be primarily due to the small volumes and low infusion rates used in these patients.

Для цитирования: Sherwin Catherine M T, McCaffrey Frances, Broadbent Roland S, Reith David M, Medlicott Natalie J. Discrepancies between predicted and observed rates of intravenous gentamicin delivery for neonates.. The Journal of pharmacy and pharmacology. 2009. DOI: 10.1211/jpp/61.04.0008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.