MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jor.23065

Медицинская библиотека · Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2015

Enhancing fixation strength in periprosthetic femur fractures by orthogonal plating-A biomechanical study.

Lenz Mark, Stoffel Karl, Gueorguiev Boyko, Klos Kajetan, Kielstein Heike, Hofmann Gunther O

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Orthogonal plate osteosynthesis enhances fixation stability in periprosthetic femur fractures. Another option are locking attachment plates (LAP) allowing bicortical locking screw placement lateral to the prosthesis stem. Stability of lateral plate osteosynthesis with two LAP (2LAP) was compared to anterolateral orthogonal plate osteosynthesis (OP) with one LAP in a periprosthetic femur fracture model. In six pairs of fresh frozen human femora with cemented Charnley hip prosthesis, a transverse osteotomy was set distal to the tip of the prosthesis simulating a Vancouver type B1 fracture. Each pair was instrumented using a plate tensioner with either one lateral plate and two LAP, or two orthogonal anterolateral plates and one LAP. Stiffness was determined in a four-point-bending test prior to cyclic testing (2Hz) with physiologic profile and progressively increasing load up to catastrophic construct failure. Paired t-test and Wilcoxon-signed-rank test were used for statistical evaluation at a level of significance p = 0.05. The OP construct exhibited a significantly higher number of cycles and load to failure (39,627 cycles ± 4,056; 4,463 N ± 906) compared to the 2LAP construct (32,927 cycles ± 3,487; 3,793 N ± 849), p < 0.01. Mediolateral bending and torsional stiffness of the OP (1610 N/mm ± 249; 16.9 Nm/mm ± 6.3) were significantly higher compared to 2 LAP (1077 N/mm ± 189; 12.1 Nm/mm ± 3.9), p = 0.03 for both comparisons. Orthogonal plate osteosynthesis is a valuable option in periprosthetic fracture surgery, offering increased stability compared to a single lateral plate fixed with two LAP.

Для цитирования: Lenz Mark, Stoffel Karl, Gueorguiev Boyko, Klos Kajetan, Kielstein Heike, Hofmann Gunther O. Enhancing fixation strength in periprosthetic femur fractures by orthogonal plating-A biomechanical study.. Journal of orthopaedic research : official publication of the Orthopaedic Research Society. 2015. DOI: 10.1002/jor.23065.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.