Effects of right- versus left-arm injections of contrast material on computed tomography of the head and neck.

You Su Yeon, Yoon Dae Young, Choi Chul Soon, Chang Suk Ki, Yun Eun Joo, Seo Young Lan, Lee Yu-Jin, Moon Jeung Hee

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To investigate the effects of the right- and left-arm injections of contrast material on image quality in computed tomography of the head and neck.

METHODS

Sixty patients were prospectively and randomly assigned into 2 groups. Eighty milliliters of contrast material (iodine concentration, 300 mg/mL) was administered into the right (n = 30) or the left (n = 30) antecubital vein at a 2-mL/s injection rate. The attenuation of the carotid artery (CA) and the internal jugular vein (IJV) was measured at 1.5-second intervals in each patient. The mean attenuation values for CA and IJV, the time to reach peak attenuation, the duration of diagnostic window (both CA and IJV enhancement were greater than 150 HU), the perivenous artifacts, and the retrograde flow of contrast material column from the subclavian or brachiocephalic vein were statistically compared between patients with right-arm injection and those with left-arm injection.

RESULTS

The mean attenuation values in CA and IJV were slightly higher in patients with right-arm injection than in those with left-arm injection, although no significant difference was reached (P = 0.06 for CA and 0.07 for IJV). The right-arm injection resulted in significantly reduced perivenous artifacts and retrograde flow of contrast material column. There were no significant differences in the time to reach the peak attenuation and in the duration of the diagnostic window between the 2 groups.

CONCLUSIONS

The right-arm injection of contrast material may provide better image quality in the computed tomography of the head and neck when compared with the left-arm injection.

Для цитирования: You Su Yeon, Yoon Dae Young, Choi Chul Soon, Chang Suk Ki, Yun Eun Joo, Seo Young Lan, Lee Yu-Jin, Moon Jeung Hee. Effects of right- versus left-arm injections of contrast material on computed tomography of the head and neck.. Journal of computer assisted tomography. 2007. DOI: 10.1097/rct.0b013e318038d8fb.