DOI 10.1016/j.arth.2022.01.094
Posterior-Stabilized Antibiotic Cement Articulating Spacer With Endoskeleton-Reinforced Cam Reduces Rate of Post-Cam Mechanical Complications in Prosthetic Knee Infection: A Preliminary Study.
Аннотация
BACKGROUND
Posterior-stabilized antibiotic cement articulating spacers (PS spacers) reduce spacer mechanical complications in prosthetic knee infections (PKIs); however, joint dislocation after femoral cam fracture has been reported. We hypothesized that the rate of post-cam mechanical complications is lower in PS spacers with an endoskeleton-reinforced cam.
METHOD: A retrospective study of PKIs using PS spacers with or without a Kirschner wire-reinforced cam (K-PS or nK-PS spacers, respectively) was conducted between 2015 and 2019. The rates of post-cam mechanical complications and reoperation, as well as risk factors for post or cam failure, were analyzed.
RESULTS
The cohort included 118 nK-PS and 49 K-PS spacers. All patients were followed up for 2 years. The rate of joint subluxation/dislocation after femoral cam fracture was lower in K-PS (0%) than in nK-PS spacers (17.8%; P = .002). The reoperation rate for spacer mechanical complications was lower in K-PS (0%) than in nK-PS spacers (11.9%; P = .008). The identified risk factors for femoral cam fractures were body mass index ≥25 kg/m2, femoral spacer size ≤2, and surgical volume ≤12 resection arthroplasties per year.
CONCLUSION
This preliminary study highlights that K-PS spacers have a lower rate of post-cam mechanical complications than nK-PS spacers. We recommend the use of PS spacers with endoskeleton-reinforced cam when treating PKIs performed by surgeons with lower surgical volumes, especially in patients with higher body mass index and smaller femoral spacer sizes.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.