m+Medelevator.RU
← Поиск публикаций
Journal of radiation research · 2026

Imaging dose in image-guided radiotherapy for localized prostate intensity-modulated radiotherapy: a nationwide survey in Japan.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kito Satoshi, Takizawa Takeshi, Tanabe Satoshi, Suda Yuhi, Nagahata Tomomasa, Tohyama Naoki, Okamoto Hiroyuki, Kodama Takumi, Fujita Yukio, Miyashita Hisayuki, Shinoda Kazuya, Kurooka Masahiko, Shimizu Hidetoshi, Ohno Takeshi, Sakamoto Masataka

Аннотация

This study aimed to establish the diagnostic reference levels (DRLs) of imaging doses for image-guided radiotherapy (IGRT) used in intensity-modulated radiotherapy for prostate cancer in Japan. A nationwide survey was conducted to gather data on image acquisition conditions, parameters, and frequencies across 193 radiation therapy institutions using intensity-modulated radiotherapy. IGRT modalities, such as kilovoltage and megavoltage cone-beam computed tomography (CBCT), two-dimensional imaging, and in-room computed tomography (CT), were targeted. Data analysis focused on image acquisition parameters displayed by the devices, such as tube voltage, current, and imaging dose, along with the CT dose index volume (CTDIvol) and dose-length product (DLP), were collected from 222 radiotherapy devices. The results showed that kV-CT/CBCT was the most frequently used modality, used in 94% of the institutions. Imaging dose-reduction techniques were adopted by over half of the institutions, with 56% optimizing imaging parameters and 45% reducing the imaging field size or scan length. The 75th percentile for CTDIvol was 16.0 mGy, while that for DLP was 263 mGy·cm, with considerable variation among devices and institutions. This study provides the first large-scale reference data for IGRT imaging doses used for prostate cancer treatment in Japan. These results are critical for improving patient safety by optimizing imaging protocols and establishing DRLs tailored to IGRT. These findings will serve as a basis for further refinement of radiological protection practices in Japan.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты