MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/echo.13842

Медицинская библиотека · Echocardiography (Mount Kisco, N.Y.) · 2018

Angiography vs transesophageal echocardiography-guided patent foramen ovale closure: A propensity score matched analysis of a two-center registry.

Scacciatella Paolo, Meynet Ilaria, Giorgi Mauro, Biava Lorenza M, Matranga Ivana, Biasco Luigi, Omedè Pierluigi, Orzan Fulvio, Gaita Fiorenzo

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVES

The purpose of this study is to compare the long-term outcomes of patent foramen ovale (PFO) closure using angiography or transesophageal echocardiography as procedural guidance.

BACKGROUND

The interventional treatment is emerging as a safe and efficient option for patients with high likelihood of PFO-related cryptogenic stroke and high risk of recurrence. The "gold-standard" guidance technique remains an issue.

METHODS

Two cohorts of patients undergoing PFO closure for cryptogenic stroke in two catheterization laboratories of the same institution, using similar inclusion criteria but different guidance, were compared with propensity score matching.

RESULTS

A total of 374 patients were enrolled, 161 in Angio-group and 213 in Echo-group. No difference was detected in the procedural complication rate. In Angio-group, radiological exposure (P = .001) and 6-month residual shunt (16.8% vs 8.0%, P = .015) were higher. After a mean follow-up of 41 ± 30 months, 28 patients (7.5%) presented any adverse event (death, recurrent cerebral ischemia, device-related complications, reintervention), with a higher rate in Angio-group (13.0% vs 3.3%, P = .001), mainly due to repeated percutaneous intervention (10.6% vs 1.4%, P = .001). The results were confirmed after propensity score matching (118 patients/group). The rate of recurrent cerebral ischemia was 1.9% and was not significantly different in the two groups. Intra-procedural guidance and atrial septum aneurysm were independent predictors of the composite primary endpoint (OR 1.2, P = .016).

CONCLUSIONS

The use of intra-procedural transesophageal echocardiography (TEE) guidance for PFO closure allows lower residual shunt rate, radiological exposure, and adverse events, mainly driven by a significant reduction in percutaneous reintervention.

Для цитирования: Scacciatella Paolo, Meynet Ilaria, Giorgi Mauro, Biava Lorenza M, Matranga Ivana, Biasco Luigi, Omedè Pierluigi, Orzan Fulvio, Gaita Fiorenzo. Angiography vs transesophageal echocardiography-guided patent foramen ovale closure: A propensity score matched analysis of a two-center registry.. Echocardiography (Mount Kisco, N.Y.). 2018. DOI: 10.1111/echo.13842.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.