BACKGROUND

Remapping studies have evaluated chronic lesion durability of the first-generation pentaspline pulsed field ablation (PFA) catheter that did not have integrated electroanatomical mapping. By invasive remapping, this first-in-human study evaluated the durability of lesions facilitated by the integration of the navigation-enabled pentaspline PFA catheter and mapping system in patients with atrial fibrillation.

METHODS

The NAVIGATE-PF Phase 2 trial evaluated the second-generation, mapping-integrated pentaspline PFA catheter. Lesion durability was assessed by invasive remapping 60 days post index procedure.

RESULTS

After index ablation in 20 patients with the pentaspline PFA catheter, remaps were performed 60 days later in 17 patients, demonstrating a high rate of lesion durability in the pulmonary veins (95%) and posterior wall (86%).

CONCLUSIONS

By facilitating real-time visualization of catheter positioning and acute lesion estimation through tags, the second-generation map-and-ablate pentaspline PFA catheter and integrated mapping system may enhance procedural success.

REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT06175234.

Для цитирования: Reddy Vivek Y, Petru Jan, Funasako Moritoshi, Canepa Silvia, Metzdorff Camille, Okeson Brynn, Mikos Evripidis, Oesterlein Tobias, Gutbrod Sarah R, Koop Brendan E, Neuzil Petr. Lesion Durability of the Second Generation Pentaspline Pulsed Field Ablation Catheter NAVIGATE-PF Phase 2 Results.. Circulation. Arrhythmia and electrophysiology. 2026. DOI: 10.1161/circep.125.014477.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.