MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/01.cir.64.4.744

Медицинская библиотека · Circulation · 1981

A new, simplified and accurate method for determining ejection fraction with two-dimensional echocardiography.

Quinones M A, Waggoner A D, Reduto L A, Nelson J G, Young J B, Winters W L, Ribeiro L G, Miller R R

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

A new method to determine left ventricular (LV) ejection fraction (EF) with wide-angle, two-dimensional echocardiography (2-D echo) has been developed using the parasternal long-axis, apical four-chamber and apical long-axis views. End-diastolic and end-systolic measurements of LV short axes at the base and mid-LV cavity in the parasternal long-axis view and at the upper, middle and lower thirds of the cavity in the apical views are made, from which an averaged minor axis at end-diastolic and at end-systole is calculated. Fractional shortening of the LV long axis (delta L) is estimated from apical contraction. Satisfactory 2-D echoes were obtained in 55 of 58 nonselected patients (all three views in 32 patients, two views in 22 and one view in one); 42 of 55 patients had coronary artery disease. EF by 2-D echo was compared with EF by gated cardiac blood pool imaging in all patients (r = 0.927, SEE = 6.7%) and to EF by single-plane cineangiography (angio) in 35 of 55 patients (r = 0.913, SEE = 7.4%). LV dyssynergy was frequently present and involved the apex in 29 of 55 patients. Using angio as the standard for evaluating wall motion at the apex, 2-D echo was 100% sensitive and specific in detecting abnormal apical wall motion. We conclude that EF can be determined accurately with 2-D echo in a large group of patients with and without dyssynergy by a simple method that eliminates the need for planimetry or computer assistance.

Для цитирования: Quinones M A, Waggoner A D, Reduto L A, Nelson J G, Young J B, Winters W L, Ribeiro L G, Miller R R. A new, simplified and accurate method for determining ejection fraction with two-dimensional echocardiography.. Circulation. 1981. DOI: 10.1161/01.cir.64.4.744.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.