MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000166946

Медицинская библиотека · American journal of nephrology · 1985

Dialyzer hypersensitivity syndrome: possible role of allergy to ethylene oxide. Report of 4 cases and review of the literature.

Caruana R J, Hamilton R W, Pearson F C

Клинический случайСтатьяОбзорПеревод в очереди

Аннотация

The occurrence of hypersensitivity reactions in patients dialyzed on artificial kidneys is well recognized in the dialysis community, but has received little attention in the medical literature. We report 4 cases of dialyzer hypersensitivity reactions and review the previously reported cases. Dialyzer hypersensitivity syndrome presents as an acute anaphylactoid reaction, the symptoms of which may range from mild to life threatening in severity. The cause of this syndrome is unknown, but affected patients appear to have a high incidence of positive radioallergosorbent tests to a conjugate of human serum albumin and ethylene oxide, suggesting that ethylene oxide, a substance used to dry sterilize artificial kidneys, may be an offending allergen.

Для цитирования: Caruana R J, Hamilton R W, Pearson F C. Dialyzer hypersensitivity syndrome: possible role of allergy to ethylene oxide. Report of 4 cases and review of the literature.. American journal of nephrology. 1985. DOI: 10.1159/000166946.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.