MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jopr.12671

Медицинская библиотека · Journal of prosthodontics : official journal of the American College of Prosthodontists · 2017

Preparation Ferrule Design Effect on Endocrown Failure Resistance.

Einhorn Michael, DuVall Nicholas, Wajdowicz Michael, Brewster John, Roberts Howard

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the effect of preparation ferrule inclusion with fracture resistance of mandibular molar endocrowns.

MATERIALS AND

METHODS

Recently extracted mandibular third molars were randomly divided into 3 groups (n = 12) with the coronal tooth structure removed perpendicular to the root long axis approximately 2 mm above the cemento-enamel junction with a slow-speed diamond saw. The pulp chamber was exposed using a diamond bur in a high-speed handpiece with pulpal remnants removed and canals instrumented using endodontic hand instruments. The chamber floor was restored using a resin core material with a two-step, self-etch adhesive and photopolymerized with a visible light-curing unit to create a 2 mm endocrown preparation pulp chamber extension. One and two millimeter ferrule height groups were prepared using a diamond bur in a high-speed handpiece following CAD/CAM guidelines. Completed preparation surface area was determined using a digital measuring microscope. Scanned preparations were restored with lithium disilicate restorations with a self-adhesive resin luting agent. All manufacturer recommendations were followed. Specimens were stored at 37°C/98% humidity and tested to failure after 24 hours at a 45° angle to the tooth long axis using a universal testing machine. Failure load was converted to MPa using the available bonding surface area with mean data analyzed using Kruskal-Wallis/Dunn (p = 0.05).

RESULTS

Calculated failure stress found no difference in failure resistance among the three groups; however, failure load results identified that the endocrown preparations without ferrule had significantly lower fracture load resistance. Failure mode analysis identified that all preparations demonstrated a high number of catastrophic failures.

CONCLUSIONS

Under the conditions of this study, ferrule-containing endocrown preparations demonstrated significantly greater failure loads than standard endocrown restorations; however, calculated failure stress based on available surface area for adhesive bonding found no difference between the groups. Lower instances of catastrophic failure were observed with the endocrown preparations containing 1 mm of preparation ferrule design; however, regardless of the presence of ferrule, this study found that all endocrown restorations suffered a high proportion of catastrophic failures but at loads greater than reported under normal masticatory function.

Для цитирования: Einhorn Michael, DuVall Nicholas, Wajdowicz Michael, Brewster John, Roberts Howard. Preparation Ferrule Design Effect on Endocrown Failure Resistance.. Journal of prosthodontics : official journal of the American College of Prosthodontists. 2017. DOI: 10.1111/jopr.12671.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.