MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2214/ajr.180.3.1800681

Медицинская библиотека · AJR. American journal of roentgenology · 2003

Using slow-infusion MR arteriography and an implantable port system to assess drug distribution at hepatic arterial infusion chemotherapy.

Seki Hiroshi, Ozaki Toshirou, Takaki Satoshi, Ooi Hiroyuki, Oda Junichi, Shiina Makoto

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The purpose of this study was to assess perfusion patterns seen on slow-infusion MR arteriography using the hepatic arterial infusion system compared with those seen on CT arteriography.

SUBJECTS AND

METHODS

In 37 patients with liver metastases who had implantable port systems for hepatic arterial infusion chemotherapy, slow-infusion MR arteriography using an infusion rate of 10 mL/hr through an implantable port and CT arteriography using an injection rate of 0.7 mL/sec were performed. In 15 of 37 patients, we evaluated enhancement patterns of tumors of the liver and visceral organs using slow-infusion MR arteriography. In all 37 patients, we compared slow-infusion MR arteriography with CT arteriography concerning intra- and extrahepatic perfusion patterns.

RESULTS

On slow-infusion MR arteriography performed 10-20 min after initiation of infusion, tumors of the liver revealed significant enhancement with only a slight effect of systemic enhancement. In seven (19%) of 37 patients, intrahepatic distributions on slow-infusion MR arteriography differed from those on CT arteriography. In eight patients, the patterns of extrahepatic perfusion into the duodenum and the pancreas head differed on slow-infusion MR arteriography from those seen on CT arteriography. In addition, strong artifact caused by platinum coils in the gastroduodenal artery interfered with the evaluation of perfusion in the area around the coils on CT arteriography, whereas no imaging artifact was seen on slow-infusion MR arteriography.

CONCLUSION

We believe that slow-infusion MR arteriography reflects the actual distribution of infused drugs more accurately than CT arteriography. When clinical complications occur during treatment, slow-infusion MR arteriography should be used to assess perfusion abnormalities.

Для цитирования: Seki Hiroshi, Ozaki Toshirou, Takaki Satoshi, Ooi Hiroyuki, Oda Junichi, Shiina Makoto. Using slow-infusion MR arteriography and an implantable port system to assess drug distribution at hepatic arterial infusion chemotherapy.. AJR. American journal of roentgenology. 2003. DOI: 10.2214/ajr.180.3.1800681.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.