Biphasic Positive Airway Pressure or Continuous Positive Airway Pressure: A Randomized Trial.

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Victor Suresh, Roberts Stephen A, Mitchell Simon, Aziz Huma, Lavender Tina, Extubate Trial Group

Аннотация

BACKGROUND: There is currently no clear evidence that nasal-biphasic positive airway pressure (n-BiPAP) confers any advantage over nasal-continuous positive airway pressure (n-CPAP). Our hypothesis was that preterm infants born before 30 weeks' gestation and <2 weeks old when extubated onto n-BiPAP will have a lower risk of extubation failure than infants extubated onto n-CPAP at equivalent mean airway pressure.

METHODS: We conducted an unblinded multicenter randomized trial comparing n-CPAP with n-BiPAP in infants born <30 weeks' gestation and <2 weeks old. The primary outcome variable was the rate of extubation failure within 48 hours after the first attempt at extubation. Block randomization stratified by center and gestation (<28 weeks or ≥28 weeks) was performed.

RESULTS: A total of 540 infants (270 in each group) were eligible to be included in the statistical analysis; 57 (21%) of n-BiPAP group and 55 (20%) of n-CPAP group failed extubation at 48 hours postextubation (adjusted odds ratio 1.01; 95% confidence interval 0.65-1.56; P = .97). Subgroup analysis of infants born before and after 28 weeks' gestation showed no significant differences between the 2 groups. There were no significant differences between arms in death; oxygen requirement at 28 days; oxygen requirement at 36 weeks' corrected gestation; or intraventricular hemorrhage, necrotizing enterocolitis requiring surgery, or pneumothorax.

CONCLUSIONS: This trial shows that there is no added benefit to using n-BIPAP over n-CPAP at equivalent mean airway pressure in preventing extubation failures in infants born before 30 weeks' gestation and <2 weeks old.