MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/vec.13272

Медицинская библиотека · Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001) · 2022

Caudal vena cava measurements and fluid responsiveness in hospitalized cats with compromised hemodynamics and tissue hypoperfusion.

Donati Pablo A, Tunesi Marcela, Araos Joaquin

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the use of the caudal vena cava collapsibility index (CVCCI) and the inspiratory/minimum and expiratory/maximum diameters of the vena cava to predict fluid responsiveness in hospitalized, critically ill cats with hemodynamic and tissue perfusion abnormalities.

DESIGN

Diagnostic test study in a prospective cohort of hospitalized cats.

SETTING

Private practice referral hospital.

ANIMALS: Twenty-four hospitalized cats with spontaneous breathing and compromised hemodynamics and tissue hypoperfusion.

INTERVENTIONS: Ultrasonographic examination before and after fluid expansion with 10 ml/kg of lactated Ringer's solution.

MEASUREMENTS AND MAIN

RESULTS

Fluid responsiveness was evaluated using the velocity-time integral (VTI) of the subaortic blood flow, by measuring it before and after a fluid load of 10 ml/kg of lactated Ringer's solution. The CVCCI was calculated using the following formula: (maximum diameter - minimum diameter / maximum diameter) × 100. Ten cats were fluid responders (42 %) and 14 were nonresponders (58 %). The area under the receiver operating characteristic curve (AUROC) with their 95% confidence interval for the predictors and the best cutoff values were as follows: CVCCI, AUROC = 0.83 (0.66-1.00) and cutoff = 31%; inspiratory/minimum diameter, AUROC = 0.86 (0.70-1.00) and cutoff = 0.24 cm; expiratory/maximum diameter, AUROC = 0.88 (0.74-1.00) and cutoff = 0.22 cm. A significant lineal correlation was observed between the percentage of increase in VTI after expansion and CVCCI (rs  = 0.68, P < 0.001), expiratory/maximum diameter (rs  = -0.72, P < 0.001), and inspiratory/minimum diameter (rs  = -0.71, P < 0.001). The intraobserver and interobserver variability was low for VTI, and the expiratory/maximum diameter and inspiratory/minimum diameter were high for CVCCI.

CONCLUSIONS

Caudal vena cava measurements could be useful to predict the response to fluids in hospitalized cats with hemodynamic and tissue perfusion alterations. Additional studies are required to draw definitive conclusions about the role of these variables to guide fluid administration in cats.

Для цитирования: Donati Pablo A, Tunesi Marcela, Araos Joaquin. Caudal vena cava measurements and fluid responsiveness in hospitalized cats with compromised hemodynamics and tissue hypoperfusion.. Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001). 2022. DOI: 10.1111/vec.13272.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.