MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/trf.13618

Медицинская библиотека · Transfusion · 2016

Serologic screening of United States blood donors for Babesia microti using an investigational enzyme immunoassay.

Levin Andrew E, Williamson Phillip C, Bloch Evan M, Clifford Joan, Cyrus Sherri, Shaz Beth H, Kessler Debra, Gorlin Jed, Erwin James L, Krueger Neil X, Williams Greg V, Penezina Oksana, Telford Sam R, Branda John A, Krause Peter J, Wormser Gary P, Schotthoefer Anna M, Fritsche Thomas R, Busch Michael P

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The tick-borne pathogen Babesia microti has become recognized as the leading infectious risk associated with blood transfusion in the United States, yet no Food and Drug Administration-licensed screening tests are currently available to mitigate this risk. The aim of this study was to evaluate the performance of an investigational enzyme immunoassay (EIA) for B. microti as a screening test applied to endemic and nonendemic blood donor populations.

STUDY DESIGN AND

METHODS

The study aimed to test 20,000 blood donors from areas of the United States considered endemic for B. microti and 10,000 donors from a nonendemic area with the investigational B. microti EIA. Repeat-reactive samples were retested by polymerase chain reaction (PCR), blood smear, immunofluorescent assay (IFA), and immunoblot assay. In parallel, serum samples from symptomatic patients with confirmed babesiosis were tested by EIA, IFA, and immunoblot assays.

RESULTS

A total of 38 of 13,757 (0.28%) of the donors from New York, 7 of 4583 (0.15%) from Minnesota, and 11 of 8363 (0.13%) from New Mexico were found repeat reactive by EIA. Nine of the 56 EIA repeat-reactive donors (eight from New York and one from Minnesota) were positive by PCR. The specificity of the assay in a nonendemic population was 99.93%. Among IFA-positive clinical babesiosis patients, the sensitivity of the assay was 91.1%.

CONCLUSION

The B. microti EIA detected PCR-positive, potentially infectious blood donors in an endemic population and exhibited high specificity among uninfected and unexposed individuals. The EIA promises to provide an effective tool for blood donor screening for B. microti in a format amenable to high-throughput and cost-effective screening.

Для цитирования: Levin Andrew E, Williamson Phillip C, Bloch Evan M, Clifford Joan, Cyrus Sherri, Shaz Beth H, Kessler Debra, Gorlin Jed, Erwin James L, Krueger Neil X, Williams Greg V, Penezina Oksana, Telford Sam R, Branda John A, Krause Peter J, Wormser Gary P, Schotthoefer Anna M, Fritsche Thomas R, Busch Michael P. Serologic screening of United States blood donors for Babesia microti using an investigational enzyme immunoassay.. Transfusion. 2016. DOI: 10.1111/trf.13618.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.