MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10856-012-4778-0

Медицинская библиотека · Journal of materials science. Materials in medicine · 2012

Artifact level produced by different femoral head prostheses in CT imaging: diamond coated silicon nitride as total hip replacement material.

Rodrigues Simone P, Paiva José M, De Francesco Silvia, Amaral Margarida I, Oliveira Filipe J, Silva Rui F

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Commercial femoral head prostheses (cobalt-chromium alloy, yttria partially stabilized zirconia (Y-PSZ) and alumina) and new silicon nitride ceramic ones (nanocrystalline diamond coated and uncoated) were compared in terms of artifact level production by computed tomography (CT). Pelvis examination by CT allows the correct diagnosis of some pathologies (e.g. prostate and colon cancer) and the evaluation of the prosthesis-bone interface in post-operative joint surgery. Artifact quantification is rarely seen in literature despite having a great potential to grade biomaterials according to their imaging properties. Materials' characteristics (density and effective atomic number), size and geometry of the prostheses can cause more or less artifact. A quantification procedure based on the calculation of four statistical parameters for the Hounsfield pixel values (mean, standard deviation, mean squared error and worst case error) is presented. CT sequential and helical scanning modes were performed. Results prove the artifact reproducibility and indicate that the cobalt-chromium and Y-PSZ are the most artifact-inducing materials, while alumina and silicon nitride (diamond coated and uncoated) ceramic ones present a low level of artifact. Considering the excellent biocompatibility and biotribological behaviour reported in earlier works, combined with the high medical imaging quality here assessed, diamond coated silicon nitride ceramics are arising as new materials for joint replacement.

Для цитирования: Rodrigues Simone P, Paiva José M, De Francesco Silvia, Amaral Margarida I, Oliveira Filipe J, Silva Rui F. Artifact level produced by different femoral head prostheses in CT imaging: diamond coated silicon nitride as total hip replacement material.. Journal of materials science. Materials in medicine. 2012. DOI: 10.1007/s10856-012-4778-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.