MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11748-023-01930-x

Медицинская библиотека · General thoracic and cardiovascular surgery · 2023

Blood flow characteristics of the bilateral internal thoracic artery: implications of optimal graft configuration for coronary artery bypass grafting to maximize blood supply.

Kunihara Takashi, Shingu Yasushige, Wakasa Satoru, Sugiki Hiroshi, Kamikubo Yasuhiro, Shiiya Norihiko, Matsui Yoshiro

СтатьяПеревод в очереди

Аннотация

PURPOSE: There is controversy regarding which internal thoracic artery (ITA) should be anastomosed to the left anterior descending artery (LAD). Here, we propose an optimal graft design based on measurement of blood flow in the ITA.

METHODS

Sixty-one patients (53 men, median age 68 [62-75] years) undergoing first elective coronary artery bypass grafting were enrolled. Fifty-seven left ITAs (LITAs) and 28 right ITAs (RITAs) were harvested in either a semi-skeletonized manner using a harmonic scalpel covered with papaverine-soaked gauze (group-A, n = 45) or a fully skeletonized manner using electrocautery with intraluminal papaverine injection (group-B, n = 41). Free flow of 33 ITAs was measured after pharmacological dilatation and in situ ITA-LAD flow was measured in 59 patients by transit-time flowmetry.

RESULTS

RITA and LITA free flow were 147.0 [87.8-213.0] mL/min and 108.0 [90.0-144.0] mL/min, respectively (P = 0.199). The group-B had significantly higher ITA free flow (135.0 [102.0-171.0] mL/min) than group-A (63.0 [36.0-96.0] mL/min, P = 0.009). In 13 patients with bilateral ITA harvesting, free flow of the RITA (138.0 [79.5-204.0] mL/min) was also significantly higher than the LITA (102.0 [81.0-138.0] mL/min, P = 0.046). There was no significant difference between RITA and LITA flow anastomosed to the LAD. The group-B had significantly higher ITA-LAD flow (56.5 [32.3-73.6] mL/min) than group-A (40.9 [20.1-53.7] mL/min, P = 0.023).

CONCLUSION

RITA provides significantly higher free flow than LITA but similar blood flow to the LAD. Full skeletonization with intraluminal papaverine injection maximizes both free flow and ITA-LAD flow.

Для цитирования: Kunihara Takashi, Shingu Yasushige, Wakasa Satoru, Sugiki Hiroshi, Kamikubo Yasuhiro, Shiiya Norihiko, Matsui Yoshiro. Blood flow characteristics of the bilateral internal thoracic artery: implications of optimal graft configuration for coronary artery bypass grafting to maximize blood supply.. General thoracic and cardiovascular surgery. 2023. DOI: 10.1007/s11748-023-01930-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.