MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/uog.13271

Медицинская библиотека · Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2014

Comparison of ultrasound and magnetic resonance imaging parameters in predicting survival in isolated left-sided congenital diaphragmatic hernia.

Bebbington M, Victoria T, Danzer E, Moldenhauer J, Khalek N, Johnson M, Hedrick H, Adzick N S

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To compare test characteristics of ultrasound- and magnetic resonance imaging (MRI)-derived parameters in predicting newborn survival in cases of isolated left-sided congenital diaphragmatic hernia (CDH).

METHODS

This was a retrospective study involving 85 fetuses with an isolated left CDH. All had detailed prenatal evaluation, prenatal care, delivery and postnatal care at a single institution. Ultrasound images were reviewed to allow calculation of the lung-to-head ratio (LHR) and the observed/expected LHR (O/E-LHR), and MRI images were reviewed to determine the observed/expected total lung volume (O/E-TLV) and the percent herniated liver (%HL). Univariable logistic regression was used to evaluate each parameter for its ability to predict survival. Receiver-operating characteristics (ROC) curves were constructed and test characteristics were determined for each parameter as a predictor of survival.

RESULTS

The overall survival for all fetuses included was 65%. Pseudo-R(2) values for all parameters were similar and were statistically significant as predictors of survival, with %HL having the highest pseudo-R(2) , of 0.28. ROC curve analysis showed ultrasound-determined parameters (LHR and O/E-LHR) to have a similar area under the curve (AUC), of 0.70, whilst MRI parameters (O/E-TLV and %HL) had AUC values of 0.82 and 0.84, respectively. At ROC-curve-determined cut-off values, MRI parameters had better test characteristics than did ultrasound parameters. At a standardized 5% false-positive rate, %HL performed best, with a sensitivity of 0.54 and a specificity of 0.95. At clinically employed cut-off values, sensitivity was similar for all parameters but MRI parameters provided the best combination of sensitivity and specificity, as evidenced by better likelihood ratios.

CONCLUSIONS

A variety of measures have been proposed as antenatal predictors of survival in CDH. Ultrasound parameters function at a similar level, whereas MRI-determined parameters appear to offer better predictive value.

Для цитирования: Bebbington M, Victoria T, Danzer E, Moldenhauer J, Khalek N, Johnson M, Hedrick H, Adzick N S. Comparison of ultrasound and magnetic resonance imaging parameters in predicting survival in isolated left-sided congenital diaphragmatic hernia.. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2014. DOI: 10.1002/uog.13271.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.