Stress distribution of single-implant-retained overdenture reinforced with a framework: A finite element analysis study.

Amaral Camilla F, Gomes Rafael S, Rodrigues Garcia Renata C M, Del Bel Cury Altair A

СтатьяПеревод в очереди

Аннотация

STATEMENT OF PROBLEM: Studies have demonstrated the effectiveness of a single-implant-retained mandibular overdenture for elderly patients with edentulism. However, due to the high concentration of stress around the housing portion of the single implant, this prosthesis tends to fracture at the anterior region more than the 2-implant-retained mandibular overdenture.

PURPOSE: The purpose of this finite-element analysis study was to evaluate the stress distribution in a single-implant-retained mandibular overdenture reinforced with a cobalt-chromium framework, to minimize the incidence of denture base fracture.

MATERIAL AND

METHODS

Two 3-dimensional finite element models of mandibular overdentures supported by a single implant with a stud attachment were designed in SolidWorks 2013 software. The only difference between the models was the presence or absence of a cobalt-chromium framework at the denture base between canines. Subsequently, the models were imported into the mathematical analysis software ANSYS Workbench v15.0. A mesh was generated with an element size of 0.7 mm and submitted to convergence analysis before mechanical simulation. All materials were considered to be homogeneous, isotropic, and linearly elastic. A 100-N load was applied to the incisal edge of the central mandibular incisors at a 30-degree angle. Maximum principal stress was calculated for the overdenture, von Mises stress was calculated for the attachment and implant, and minimum principal stress was calculated for cortical and cancellous bone.

RESULTS

In both models, peak stress on the overdenture was localized at the anterior intaglio surface region around the implant. However, the presence of the framework reduced the stress by almost 62% compared with the overdenture without a framework (8.7 MPa and 22.8 MPa, respectively). Both models exhibited similar stress values in the attachment, implant, and bone.

CONCLUSIONS

A metal framework reinforcement for a single-implant-retained mandibular overdenture concentrates less stress through the anterior area of the prosthesis and could minimize the incidence of fracture.

Для цитирования: Amaral Camilla F, Gomes Rafael S, Rodrigues Garcia Renata C M, Del Bel Cury Altair A. Stress distribution of single-implant-retained overdenture reinforced with a framework: A finite element analysis study.. The Journal of prosthetic dentistry. 2017. DOI: 10.1016/j.prosdent.2017.07.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.