MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/bios14120630

Медицинская библиотека · Biosensors · 2024

Development of Single-Walled Carbon Nanotube-Based Electrodes with Enhanced Dispersion and Electrochemical Properties for Blood Glucose Monitoring.

Kim Dong-Sup, Sobhan Abdus, Oh Jun-Hyun, Lee Jahyun, Park Chulhwan, Lee Jinyoung

СтатьяПеревод в очереди

Аннотация

The evolution of high-performance electrode materials has significantly impacted the development of real-time monitoring biosensors, emphasizing the need for compatibility with biomaterials and robust electrochemical properties. This work focuses on creating electrode materials utilizing single-walled carbon nanotubes (SWCNTs) and multi-walled carbon nanotubes (MWCNTs), specifically examining their dispersion behavior and electrochemical characteristics. By using ultrasonic waves, we analyzed the dispersion of CNTs in various solvents, including N, N-dimethylformamide (DMF), deionized water (DW), ethanol, and acetone. The findings revealed that SWCNTs achieved optimal dispersion without precipitation in DMF. Additionally, we observed that the electrical resistance decreased as the concentration of SWCNTs increased from 0.025 to 0.4 g/L, with significant conductivity enhancements noted between 0.2 g/L and 0.4 g/L in DMF. In constructing the biosensor platform, we employed 1-pyrenebutanoic acid succinimidyl ester (PBSE) as a linker molecule, while glucose oxidase (Gox) served as the binding substrate. The interaction between Gox and glucose led to a notable decrease in the biosensor's resistance values as glucose concentrations ranged from 0.001 to 0.1 M. These results provide foundational insights into the development of SWCNT-based electrode materials and suggest a promising pathway toward the next generation of efficient and reliable biosensors.

Для цитирования: Kim Dong-Sup, Sobhan Abdus, Oh Jun-Hyun, Lee Jahyun, Park Chulhwan, Lee Jinyoung. Development of Single-Walled Carbon Nanotube-Based Electrodes with Enhanced Dispersion and Electrochemical Properties for Blood Glucose Monitoring.. Biosensors. 2024. DOI: 10.3390/bios14120630.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.